Ethernet Adaptor 01-103
Sparr Electronics Ltd., Bangalore
18
C IP Address/Port Number
(No space between C and IP address).
Example: -
C192.168.0.250/25.
Note: The “C” should be in Capital only as it is Case Sensitive.
Input Character Mode: -
This Mode is selected when you require EAD to connect
automatically to Server when there is character from the Serial Port. For the input
character mode automatic connection, Remote IP address and the TCP port number
parameters are required and should be programmed. If the Input character mode is
selected (here you can program the number of characters given as input), all parameters
must be provided. (i.e. Remote IP, Remote port number, Start mode = 2). It will connect
to the programmed IP address and the port number when unit receives the number of
characters equal to the one you programmed. It will allow number of input characters
from 1 to 999.
The Default number of character is 1.
Default setting is Auto. But will behave as manual, if the Remote IP and port
numbers are set to 0 (Section 8.3.4 and 8.3.5)
It is not possible to set number of characters through web browser.
7.3.3. Accept Incoming Connection
Set the incoming connection as enable or disable. This should be enabled for a Computer
in the Network to initiate connection to the EAD01-103. This can be disabled if EAD01-
103 makes the connection to the Server and does not require connection from Server.
Default setting is Enable
7.3.4. Remote IP Address
When the start mode is Auto start (automatic connection) or based on Input Character
Mode, EAD makes a connection to this IP address on the network. This IP address should
be within your Network IP Range.
Default Setting is 0
7.3.5. Remote Port Number
The remote TCP port number must be set for automatic connections and for connection
based on Input Character Mode. This parameter defines the port number on the target host
to which a TCP connection is attempted. This works in conjunction with Remote IP
Address.
Default Setting is 0
7.3.6. Send CR with LF.
EAD in addition can send a line feed character (LF) with every Carriage return (CR)
received from the Serial Port to the Host PC, if this option is enabled. The available
option is Disable or Enable.
Default Setting is Disable