Ethernet Adaptor 01-103
Sparr Electronics Ltd., Bangalore
20
7.3.13.
DTR active on Connect Only.
DTR (Data Terminal Ready) will be activated when a network connection is established
with EAD01-103.
Default Setting is Disable.
7.3.14.
Exit
Use this option to exit and come back to the previous selection menu
7.3.15.
Defeat Long Ack.
User can Disable and Enabled delayed ACK
Default Setting is Enable.
7.3.16.
Restart on loss of link.
This option is used to set the EAD to be restarted when the network connectivity has lost.
Default Setting is Enable.
7.3.17.
Telnet IAC
7.3.18.
Telnet IAC terminal type
When Telnet IAC is Enabled, terminal type is
VT100.
7.4. Load factory defaults
Use this option to program the factory default values for all the parameters of the
EAD.
You can also load the factory defaults by pressing the „Default Switch‟ for 10
seconds continuously. Please note that the YELLOW LED (
CONNECT LED) will be
off when „LOAD FACTORY DEFAULT‟ switch is pressed continuously for 10 seconds.
After 10 minutes it will be on. Refer Default values in section 8
7.5. Change Configuration Password.
Select this option to change the password required for entering in to Configuration Mode
for making any changes to the Settings.
Default password is 77277
. This password is
needed for programming through Serial and Telnet. This will take only alphabets [A-Z, a-
z], digits [0-9] and will not allow any symbols. It must have minimum 3 characters. It will
allow maximum 9 characters