15
serial line (i.e. ETX, EOT etc.). Setting the first Sendchar to “00” disabled the
recognition of the characters. Alternatively, the two characters can be interpreted as a
sequence (see Pack control, above).
4.7.14. Telnet Terminal Type
This parameter appears only if terminal type option is enabled by setting Bit 6 in the
disconnect mode. If set, the terminal name used for setting the Telnet terminal type
exchange option can be set here. Only one name can be entered. If Terminal type option
is enabled, EAD 02 also reacts to the EOR (end of record) and binary options, which can
be used for applications like terminal emulation to IBM hosts (contact Lantronix for
details).
4.7.15. Exit Configuration Mode
To leave the configuration program and save all changes, press ‘9’. All values will be
stored in nonvolatile (E²PROM) memory, and EAD 02 will reset.
5. Configuring through Web Browser
Open your JAVA enabled web browser and enter the IP address assigned to the EAD 02.
The Web Manager page will display. The
Web Manager has following
menu selections.
Web Manager 3.0 has the following buttons:
?
Unit Configuration
?
Server Properties
?
Port Properties
?
Factory Settings 1 and Factory Settings 2 for two serial channels
?
Update Settings
?
Channel 1 and Channel 2 for devices with two serial channels)
?
Tech Support
?
FTP – Site
?
Back to Web-Manager
?
Contact Us