background image

www.spartacogroup.com 

 800-860-6170

8

OPERATING INSTRUCTIONS

  CUTTING

  MAINTENANCE AND INSPECTION

1. Retract blades by pressing the release button.
2. Be sure that material being cut is within the specified cutting capacity of the tool.
3. Place the material to be cut between the blades and press the advance trigger until blades 
hold the material in place.
4. Check material for proper alignment to the cutting blades. It should be at a 90° degree 
angle to the blades. Any other angle will cause the blades to spread apart and possibly break.

5. Continue to advance the blades until the material is cut. If material is cut and tool has not 
yet by passed, it may be difficult to retract blades. If this occurs, continue to advance tool and 
build pressure. A series of clicks will be heard while the tool running in a “neutral” mode. This 
indicates that the tool has built full pressure and bypassed and can now be released.

1. Daily maintenance is required to ensure that the tool is kept in good working condition.
2. Sharpen blades occasionally with a sharpening stone on the back side of the blades to  

 

remove any burrs that may occur.
3. Do not store the tool in a humid environment.
4. Wipe away any excess oil with a soapy cloth.
5. Provided that maintenance of the tool is carried out regularly, the tool should provide  

 

  many years of service.
6. Should you experience any difficulty with the operation and maintenance of this tool,  

 

  contact Huskie’s technical support department at 1-800-860-6170.

RIGHT!

WRONG!

Summary of Contents for Huskie Tools REC-S620

Page 1: ...n Battery Powered Cutting Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 195 Internationale Blvd Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www spartacogroup com ...

Page 2: ...oducts represents the state of the art tools and are dependable safe Trust integrity teamwork and mutual respect these words are something we take to heart here at Huskie Tools Please take the time to read this manual carefully to learn how to correctly operate and maintain your tool Table of Contents Registration Contents 2 Warranty 3 Safety 4 Kit Includes 5 Specifications 6 Operating Instruction...

Page 3: ...s containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone other than Huskie Tools LLC or an authorized service center renders this warranty null and void Repair and Warranty Claims All claims must be sent to Huskie for inspection and authorization A Return G...

Page 4: ...eye protection when operating this tool Failure to wear eye protec tion could result in serious eye injury from flying debris Electric Shock hazard Use proper personal protective equipment when using this unit on or near energized electrical lines Pinch Point Hazard Compression Dies at high force can cause severe per sonal injury Keep all body parts away from moving parts of the tool while operati...

Page 5: ...d rotating head provide exceptional ease of use and maneuverability in tight working quarters The REC S620 has an overload bypass that will kick out when the tool reaches 6 6 tons or is attempting to cut cables beyond its capacities NOTE DO NOT CUT EHS GUY WIRE OR CASE HARDENED STEEL RODS SEE REC S624CC S 24CC SP 24CC S 32CC OR SP 32CC1 1 Battery Powered Tool 1 Carrying Case 1 CH 94 Tri Chemistry ...

Page 6: ...2 Ground Rod 60 3 8 Guy Wire 40 Cutting Capabilities Wire Rope 5 8 Rebar Sc 40 1 2 Rebar Sc 60 3 8 Ground Rod 1 2 ACSR 477 MCM Guy Wire 3 8 Flip Top Latching Head Tested Up to 75kV One Hand Operation Rotational Head Bright White LED Lights for Working in Low Light Conditions Rapid Advance Ergonomically designed for balance grip Weather Resistant Housing Overload Bypass Protection 5 Year Warranty o...

Page 7: ...flashing quick amber this could be a possible short in the battery circuit or a problem with the charger itself It is best to consult the factory at 1 800 860 6170 for service if such a condition occurs 4 For technical questions or difficulty in operation please call our customer service department at 1 800 860 6170 CHARGING THE BATTERY 1 While pressing the latch pull out the battery cartridge To ...

Page 8: ...d it may be difficult to retract blades If this occurs continue to advance tool and build pressure A series of clicks will be heard while the tool running in a neutral mode This indicates that the tool has built full pressure and bypassed and can now be released 1 Daily maintenance is required to ensure that the tool is kept in good working condition 2 Sharpen blades occasionally with a sharpening...

Page 9: ...E BATTERY CARTRIDGE 1 Do not short circuit the contacts or expose the cartridge to water oil or solvents 2 Do not disassemble or attempt to repair the battery cartridge or dispose of in a fire 3 Do not drop or otherwise abuse the battery cartridge 4 Do not leave the cartridge in locations where it will be exposed to a temperature greater than 140ºF 60ºC for an extended period 5 The battery has a l...

Page 10: ...www spartacogroup com 800 860 6170 10 BREAKDOWN 60 ...

Page 11: ...t Seal EZ 14 2 19 Valve Cartridge EZ 25I 1 60 P 11 Back Up Ring B C 610F 06 2 20 Push Pin 658 06 1 61 P 11 O Ring 610F 07 1 21 3 16 Ball 16 49 2 62 G35 O Ring 658 11 2 22 Valve Screw SL5 10 1 63 Retainer SLND 14 1 23 LP control plug SL5 11 1 64 Spring 420 9H2 02 1 24 Spring 686 EZ 26 2 65 Bush R14A 19 1 25 Ram Spring 75 16 17 1 66 Filter Screen R14A 22 2 26 5 32 Ball 22 21 6 67 Blade Screw 16 19 1...

Page 12: ... Repair Service Defective Suction Valve or Bypass Cartridge Consult Factory for Repair Service MOTOR WILL NOT RUN AT ALL Defective Battery Charge or Replace Battery Bad Contact or Loose Battery Connections Check all Connections and Wires Misaligned Switch Check to Make Sure that Switch is Properly Aligned with Trigger Consult Factory for Repair Service TOOL JAWS WILL NOT RELEASE Tool Did Not Compl...

Page 13: ...NOTES ...

Page 14: ...NOTES ...

Page 15: ...NOTES ...

Page 16: ...195 Internationale Blvd Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www spartacogroup com ...