10. TECHNICAL DATA FOR FIREPLACE INSERT
Mini
R1V 51
Mini
R1V 51
NSHF
Mini
R1V / R1Vh
57
Mini
R1V / R1Vh
57 NSHF
Mini
Z1
Mini
Z1 NSHF
Mini
S / Sh
Speedy
1V / 1Vh 51
General data
Norminal heat output (kW) (closed structure)
5,2
6,2
5,0
6,0
7,0
10,0
7,0
9,0
Thermal output range (kW)
4,5 - 6,8
4,5 - 8,1
4,5 - 6,5
4,5 - 7,8
4,9 - 9,1
7,0 - 13,0
4,9 - 9,1
6,3 - 11,7
Efficiency (%)
80
> 80
> 80
> 80
> 78
> 80
> 78
80
Recommended flue diameter (mm)
160
160
160
160
180
180
180
200
Flue outlet diameter (mm)
160
160
160
160
180
180
180
200
Weight (kg) (approx.)
150
150
150
150
160
160
205
200
required minimum cross section for circulating air with WAC
700
700
700
700
700
-
700
700
required minimum cross section for circulating air
650 / 780
770 / 920
600 / 720
720 / 860
950 / 1140
1360 / 1640
810 / 890
1420 / 1710
Operation with open
door (multiple usage
of the chimney not
permitted)
Exhaust mass flow (g/s)
-
-
-
-
20,9
-
17,8
-
Exhaust gas temperature (°C)
-
-
-
-
240
-
230
-
Exhaust gas temperature behind NSHF (°C)
-
-
-
-
-
-
-
-
Required manometric pressure (Pa)
-
-
-
-
12
-
12
-
Recommended diameter in opening to secure sufficient air into the room (cm)
-
-
-
-
40
-
45
-
Operation with closed
door (multiple usage
of the chimney
permitted)
Exhaust mass flow (g/s)
4,7
6
4
5
7,5
7,6
8,8
9,2
Exhaust gas temperature (°C)
255
355
258
355
330
355
290
342
Required manometric pressure (Pa)
12
12
12
12
14
14
14
12
CO
2
(%)
9,8
8,0
11,3
10,0
8,6
11,1
7,9
12,2
Necessary area to secure air balance in the room (M-FeuVO) (cm)
15
15
15
15
15
15
15
15
Combustion air requirement (m
3
/h)
16,2
21,4
13,4
16,6
25,5
25,2
27,6
21,1
Heat distribution
Convection (%)
62
62
60
60
68
74
58
64
Glass window (%)
38
38
40
40
32
26
42
36
Water (%)
-
-
-
-
-
-
-
-
Distances to convec-
tion chamber
To the wall (cm)
9
11
9
10
10
10
9
10
To the floor (cm)
-
-
-
-
-
-
-
-
Thermal insulation*
(Example rock wool
mats in acc. with
AGI-132 Q)
Mounting wall (cm)
12
12
12
12
8
8
9 / 8
16
Floor (cm)
-
-
-
-
-
-
-
-
Lateral wall (cm)
12
12
12
12
8
8
9 / 8
16
Additional walling for wall protection (cm)
10
10
10
10
10
10
10
10
Tests and values
Type A - (no self-closing door)
-
Type A1 - (self-closing door)
BImSCHV. 1st level
BImSCHV. 2nd level
15a BVG
* From components that are combustible or need to be protected.