1. GENERAL INSTRUCTIONS

Small children, elderly or infirm people: As with all naked flames, it is always 
advisable to have a protective guard in place for these groups of people 

Risk of burning! 

Never leave these groups of people unattended near the 

the fireplace when an ebios-fire is burning or has just been extinguished!
The ebios-fire must never be left unattended while in operation!

The relevant specific regional and local directives and regulations, espe-
cially those relating to fire safety in a German federal state, and where 
applicable the fire safety stipulations of VKF governing the installation and 
operation of your ebios-fire must be observed.

The installation location must ensure that there is no possibility of the 
burner moving while in operation as a consequence of collision impacts or 
similar events.

All models may only be operated with the closed housing cover.

Please note that the fuel must not be topped up when the equipment is hot 
or in burning mode. Refilling must NOT take place via the burner channel but 
instead ONLY via the filler aperture (see Fig. 1). We advise you to put out the 
ebios-fire by running it until the fuel tank runs dry. When not in operation, 
the cover plate must always be over the burner.

Only permit people to fill the equipment with fuel who are familiar with 
the equipment and with the safety requirements, and who have received 
instructions from you in the operation of the unit.

The ebios-fire is not a heater, but is instead a decorative fire.

Bio-ethanol is a hazardous substance and must always be stored in accord-
ance with the specifications, and only in specified amounts.

Storage in the basement:  

max. 20 litres

Storage in a residential space:   max. 5 litres

1.1 SCOPE OF DELIVERY

ebios-fire with the following features:

•  ebios Chelsea / Kensington fireplace insert 
•  Manual wick burner or automatic burner
•  Bottle for wetting the burner mat (with wick burner)
•  Cold hand (with wick burner) 
•  Funnel for filling the burner (with wick burner)
•  Stick lighter (with wick burner) 
•  Remote control (with automatic burner) 
•  Rating plate 
•  Ethanol 5l canister with drain valve for commissioning (with wick 

burner)

•  Pre-assembled burner in transport-friendly disposable card-board 

packaging

2. ASSEMBLY INSTRUCTIONS

Please be sure to observe the following carefully. Please bear in mind that 
bio-ethanol is a liquid fuel that, when combusted, can produce high local 
temperatures and is itself readily ignitable. Any failure to comply with the 
assembly and operating instructions can lead to hazardous situations, and 
even to explosive combustion of the fuel. With proper installation and proper 
handling, you can assure safe and reliable operation. The equipment must 
not tilt and must be aligned horizontally. Secure the wall-mounted equip-
ment as well as the free-standing equipment to the wall and floor respec-
tively. This is for your own safety.

Summary of Contents for ebios fire Chelsea

Page 1: ...Instructions for assembly and use ebios fire Chelsea Kensington...

Page 2: ...ith our specialist trade partners first class products that touch the emotions and invite feelings of security and comfort To enable that to succeed we recommend that you read the operating man ual ca...

Page 3: ...istances for the ebios fireplace insert 8 2 7 Combustion air supply 8 3 Operating Manual 8 3 1 General information on Wick burner 8 3 2 Fuel 9 3 3 Commissioning 10 4 Cleaning and care 10 4 1 Cleaning...

Page 4: ...with the safety requirements and who have received instructions from you in the operation of the unit The ebios fire is not a heater but is instead a decorative fire Bio ethanol is a hazardous substan...

Page 5: ...LATION When installing and operating the ebios fire due compliance with all appli cable national and European standards as well as local stipulations fire protection regulations etc must be observed a...

Page 6: ...and secured to prevent tilting The fireplace inserts may only be installed in recesses with a sufficient load bearing capacity If the load bearing capacity is not sufficient suitable measures must be...

Page 7: ...L 70 25 20 200 Quadra Inside II SL 120 25 20 400 Quadra Inside III SL 175 25 20 600 Built in with automatic burner model L cm B cm H cm M cm Quadra Inside Automatik I SL 70 25 20 200 Quadra Inside Aut...

Page 8: ...d except for the burner unit Please observe the fire protection regulations and dangerous goods specifications 3 1 GENERAL INFORMATION ON WICK BURNER Small children elderly or infirm people As with al...

Page 9: ...h correspondingly less fuel If you shut the equip ment down prematurely seal the burner using the cover plate with the help of the cold hand After shutting down the burner always allow at least 1 hour...

Page 10: ...ied with an empty burner to ensure that during transportation ethanol cannot escape or evaporate Please observe the enclosed instruction manual for either the wick or auto matic burner during commissi...

Page 11: ...mbH offers a 6 months warranty on wear ing parts in the area of the fire such as wicks burner mats gaskets and ceramics 5 4 REQUIREMENT OF EFFECTIVENESS FOR THE WARRANT The warranty period starts on t...

Page 12: ...ms and conditions and undertakings We particularly advise you to have your ebios fire products serviced regularly by a stove fitter specialist dealer We reserve the right to make technical modificatio...

Page 13: ...GB 13 GB Technical data subject to change Errors and omissions excepted...

Page 14: ...GB 14 NOTES...

Page 15: ...GB 15 GB...

Page 16: ...van wereldformaat voor uw woonkamer wiatowa marka do Pa stwa salonu 1 D Ihr Fachh ndler UK Your specialist dealer F Votre revendeur sp cialis IT Il vostro rivenditore specializzato E Sus comercios esp...

Reviews: