The burner is supplied with 2 hoses. One hose is provided to supply the
ethanol. The other hose acts as an overflow. Both hoses are connected to
the same container. For safety reasons, an empty container should only be
replaced with a full one while the burner is switched off.
If the container is empty, the flame will go out and the burner will switch off.
In addition, an acoustic alarm is sounded.
Otherwise, when the burner is switched off (by remote control), the pump is
shut down. The fuel remaining in the burner channel at that time is pumped
back into the tank. The remaining ethanol burns off within about 40 sec-
onds. In isolated cases, this process can take longer.
Both hoses must always be connected to a container!
2.2 TECHNICAL DATA
Quadra Inside
Automatic I SL
Quadra Inside
Automatic II SL
Fuel type
Bioethanol
(ethanol content 96%)
Fuel consumption
approx. 0.5 l/hr
approx. 1.0 l/hr
Combustion power
3300 W
6600 W
Minimum room volume per burner *
Air exchange rate 0.2 hr-1**
418 m³
836 m³
Air exchange rate 0.5 hr-1**
167 m³
334 m³
Air exchange rate 1 hr-1**
84 m³
168 m³
Permitted humidity
max. 60% rel.
Permitted ambient temperature
0 - 40°C
Permitted mains voltage
110 - 230 VAC
Maximum power consumption
approx. 36 W
** At a maximum combustion time of 5 hours. These details relate solely to
the air required by the ebios-fire. Should you have additional air-consum-
ing devices installed in the room, these must be taken into consideration
separately.
** The following air exchange rates are given as rough guide values1):
Air exchange [1/hr]
Comments
0…0.5
Windows and doors closed
0.3…1.5
Window tilted, no roller blinds
5…10
Window half open
1)
Recknagel, Sprenger, Schrameck: Klimatechnik, Oldenbourg Verlag