3.4 STARTUP
The ebios-fire devices are supplied with empty burners to prevent any
ethanol from flowing out or evaporating during transit. Ensure (particularly
before being put into use) that there is no fuel in the safety container.
3.4.1 STARTUP OF THE MODELS ELIPSE AND
QUADRA
Proceed as follows:
1. Ensure that the air supply is sufficient. (see 2.7)
2. Make sure that the burner has gone out and has cooled down fully
(minimum waiting time after being extinguished = 1 hour).
3. The burner remains in the housing when being refilled. For this re-move
the protective panes and then open the housing cover.
4. Check the tank content.
5. Make sure that the cover plate is placed on the burner and covers the
burner mat.
6. Use a wrench to open the filling screw.
7. Insert the funnel into the filling opening and pour in a maximum of 2.6
l of bioethanol.