GB
8
• In areas which are not protected against transverse ventilation
• On tables, pieces of furniture, shelves etc.
• In entrance areas of hotel lobbies, bars, restaurants etc. where higher
air change rates can be expected. (draught)
2.5 INSTALLATION / ASSEMBLY
The ebios-fire model, whether as a floor- or wall-mounted version, must be
aligned horizontally and protected from tilting. Secure wall-mounted models
to the wall and floor-mounted models to either the wall or the floor. Please
note the safety distances (Fig. 4 radiation area). Rear ventilation must not
be closed. Place the burner with safety container and cover plate in the
designated holders in the furniture.
Floor-mounted furniture may only be set up on floors with sufficient load-
bearing capacity. If the load bearing capacity is not sufficient, suitable
measures must be taken (e.g., plate for load distribution) to remedy this.
Use suitable fastening material (wall plugs, screws etc.) when securing to
the wall.
After installing the wall-mounted appliance on the wall, the appliance is to
be secured from being accidentally pushed upwards/dismounted using the
spin-lock.
Thread