3.9 EXAMPLE INSTALLATION
A
Fireplace cassette
B
Insulation
C
Masonry work
D
Wall made of combustible materials/components or load-bearing walls
E
Convection air pipe
E1 = 10mm (distance if an adjacent construction component has no requirements)
E2 = 60mm (distance to combustible construction materials)
F
Ceiling made of combustible construction materials or combustible construction components
G
Casing
H
Flooring made out of non-combustible construction materials
Fig.5
Fig.6
4. INSTALLATION
4.1 INSTALLATION OF THE FIREPLACE CASSETTE
INTO AN EXISTING FIREPLACE
• Clean the firebox in the existing open fireplace thoroughly.
• Installation measures that bring about any restriction to the open fire-
place and reduce safety are not permitted.
• Check whether the flooring of the existing fireplace is level. Slight
unevenness can be balanced out later via the adjustable feet using an
Allen key.
• The prescribed minimum thermal insulation for the whole fireplace - cal-
culated according to DIN EN 13229 - must be adhered to if the existing
open fireplace was not expertly constructed.
• In order to prevent fires and deflagration, it is important to ensure that
there are no dangerous deposits in the exhaust gas collection chamber.
These critical areas must be constructed in such a way that soot parti-
cles and flying ash can fall back into the firebox. This can be achieved
using deflectors or through corresponding lining with fire-clay or refrac-
tory concrete. Access is made possible through the cleaning openings.
• Install the exhaust gas flue system in the existing chimney. This must
be a flexible system according to DIN EN 1856-T2 but it may vary from
country to country.
Attention:
The fireplace cassette has not yet been
fitted at this stage! The required process steps for connecting the flex-
ible exhaust gas flue system to the exhaust gas socket on the fireplace
cassette are listed here:
- Dismantle the deflector plate by firstly removing both of the side blocks
of the firebox lining.
- Loosen the two screws securing the exhaust gas connection and place
it laterally into the combustion chamber (Fig. 7).
- Now remove the exhaust gas socket from the fireplace cassette and
connect this socket to the flexible exhaust gas pipe inside the open
fireplace. The linear measurement of the flexible exhaust gas pipe
should be the actual length required so that the flexible pipe cannot be