1. CERTIFIED QUALITY / DEFINITION

Our fireplace cassettes are tested according to DIN 13229.

This family of cassettes can be installed in five standard sizes (500-900) 
into, for example, existing open fireplaces. However, it is also possible to 
install the fireplace cassette in a similar way to a fireplace insert if the 
appropriate tests have been completed. This includes taking into account 
the relevant sizes of the air supply and recirculation openings. 

The fireplace cassettes have a self-closing firebox door so that the door 
is only opened for operating the fireplace (e.g. cleaning the firebox or for 
putting more fuel on the fire). It is not permitted to tamper with the closing 
mecha-nism for safety reasons and should this occur it will invalidate the 
guarantee and the approval to use the fireplace cassette. The guarantee and 
the approval to use the fireplace cassette are also invalidated if the cassette 
is technically modified in any other area by the customer.

1.1 SCOPE OF DELIVERY

A fireplace cassette with the following characteristics:
•  Firebox made of refractory concrete/vermiculite
•  Primary and secondary airflow systems
•  Self-closing firebox door with a high temperature-resistant ceramic 

glass panel

•  Heat-resistant gloves
•  Type plate (mounting location, see 5.2)

1.2 TRANSPORT DAMAGE

Please immediately check the goods on delivery (visual inspection). Note 
any damage that may have occurred on your delivery note and then please 
inform your fireplace fitter. Protect the visible parts of the cassette from 
soiling or damage during installation.Only approved transport aids with suf-
ficient load-bearing capacity may be used for transporting your fireplace 
cassette. The following points must be observed for safe and uncomplicated 
transport:

•  The fireplace cassette must generally only be transported either in an 

upright position or slightly inclined onto its rear!

•  If a hand truck is being used as a transport aid, this may only be posi-

tioned at the rear of the cassette.

2. INSTALLATION INSTRUCTIONS

Your fireplace cassette may only be assembled and installed by a specialist 
fireplace fitter. You should talk to the responsible heating inspector/chimney 
sweep in your district before setting up and installing the fireplace cassette 
in order to clarify the suitability of your chimney and installation location, as 
well as for any other possible issues.

Summary of Contents for L 800

Page 1: ...GB Installation and Operating Instructions Linear Fireplace Cassettes...

Page 2: ...otional level creating feelings of security and comfort To ensure this is achieved we recommend that you carefully read these operating instructions so that you can become quickly and comprehen sively...

Page 3: ...needing protection 13 3 7 Expansion joint between the casing and the fireplace cassette 13 3 8 Combustion chamber design 13 3 9 Example installation 15 4 Installation 15 4 1 Installation of the firepl...

Page 4: ...the outer casing of the fireplace cassette can become very hot Risk of burning Never allow these groups of people to touch or use a fireplace cassette without supervision when a fire is lit or has jus...

Page 5: ...ncrete vermiculite Primary and secondary airflow systems Self closing firebox door with a high temperature resistant ceramic glass panel Heat resistant gloves Type plate mounting location see 5 2 1 2...

Page 6: ...1 2 Exhaust gas systems residential chimneys Fireplaces may only be installed in rooms and locations where no danger results from their position structural conditions and type of use The sur face are...

Page 7: ...oved for multiple installations 2 3 TECHNICAL DATA DIMENSION SHEETS The following information has been taken from the testing report and cor responds to the testing conditions Fireplace cassette XS 50...

Page 8: ...H 130 150 150 150 150 I 352 412 442 472 502 J 100 convection air openings 125 Dimensions Linear cassettes Linear XS 500 mm Linear S 600 mm Linear M 700 mm Linear L 800 mm Linear XL 900 mm K 400 566 66...

Page 9: ...Optional convection air sockets 100mm 1 Cassette frame 60 80 100 mm 2 Firebox door with ceramic glass 3 Firebox lining 4 Firebox 5 Inspection maintenance openings 6 Exhaust gas sockets rotatable vert...

Page 10: ...the position of the operating handle 2 7 GENERAL REQUIREMENTS FOR THE USE OF FIREPLACE CASSETTES IN EXISTING FIREPLACES The fireplace cassettes are suitable amongst other things for retrofitting into...

Page 11: ...ot be closed Ensure that there is sufficient combustion air minimum 360 m per hour and m of the firebox opening The fireplace cassette can be connected to a flexible exhaust gas flue which is fed thro...

Page 12: ...nents The insulation thicknesses listed are based on the reference insulation material rock wool according to AGI Q 132 Silicon based insulation material can also be used with the relevant building ap...

Page 13: ...s to be reduced significantly 3 7 EXPANSION JOINT BETWEEN THE CASING AND THE FIREPLACE CASSETTE There must be no direct connection between the fireplace cassette and the casing An expansion joint is t...

Page 14: ...200 mm 60 mm XL 900 40 mm 60 mm 200 mm 60 mm Rock wool mats to AGI Q 132 Linear cassette Setup floor Mounting wall Ceiling Side wall XS 500 0 mm 50 mm 50 mm 60 mm S 600 0 mm 160 mm 120 mm 80 mm M 700...

Page 15: ...o prevent fires and deflagration it is important to ensure that there are no dangerous deposits in the exhaust gas collection chamber These critical areas must be constructed in such a way that soot p...

Page 16: ...additional thermal protection e g air deflector plate when they are within the thermal radiation field or are located in the area of the cassette s thermal air convection field This is particularly i...

Page 17: ...sulated from the room s air 4 4 INSTALLING OR DISMANTLING THE FIREBOX INTO FROM THE CONVECTION AIR JACKET The firebox can be dismantled from the convection air jacket in its installed state Reasons fo...

Page 18: ...blower then you only need to connect the plug to a properly earthed electricity socket The following steps should be carried out for maintenance inspection of the hot air blower 1 Dismantle the cover...

Page 19: ...he control shaft is inserted through two holes in the frame when installing the frame It may be necessary to order a new cassette frame if the existing one does not have any corresponding holes 4 7 DI...

Page 20: ...to the fixture move the door a little swivel the door 3 Loosen the hexagonal socket on the lower hinge with a 3 mm Allen key 4 Close the door and then push the safety clasp back onto the pin 4 8 INSTA...

Page 21: ...ith cross slot Ensure that you initially screw the screws in loosely Tighten then only once all of the screws are screwed in 3 The exhaust gas connection is inserted into the exhaust gas socket This i...

Page 22: ...L XL Linear XS 500 mm Linear S 600 mm Linear M 700 mm Linear L 800 mm Linear XL 900 mm 1 1 2 1032854 1017402 1017404 1017406 1017408 2 2 1017403 1017405 1017407 1017409 3 2 2 1032859 1017459 1017459...

Page 23: ...e appliance must not be operated with the appliance door left open except as directed in the instructions The fireplace cassette may only be operated when the firebox door is closed The door must also...

Page 24: ...a good level of room ventilation during this burning process Open all doors and windows to the outside Please note minor expansion or stress noises can occur during heating or cooling of the fireplac...

Page 25: ...f required leave the fire box door open by approx 3 5 cm The fire should now light burning brightly and intensively 8 When the kindling wood is burning well add smaller hardwood logs or larger softwoo...

Page 26: ...mod ern houses built after 1990 However the old information for room heating capacity can still be of interest as a comparative value or for use with older building structures that do not yet correspo...

Page 27: ...transitional period meaning when the outside temperature is still high above approx 15 C or during unfavourable weather conditions katabatic winds etc it is possible to experience disruption to the ch...

Page 28: ...clear as pos sible the less visible the exhaust gas appears the better the burning process Wood originating from Europool palettes Waste household rubbish or old clothing Paper paper briquettes carton...

Page 29: ...leaned in a cold state Please note that cleaning can lead to soiling of the installation room and your clothing We recommend that you protect the area around the opening to the fire place from soiling...

Page 30: ...be easily cleaned using standard fireplace glass cleaner which you can also obtain from your specialist dealer The glass fibre seals should not be soaked with cleaning fluids Finally wipe the glass p...

Page 31: ...es on or may pass on to its customers in a particular case 8 2 GENERAL INFORMATION This quality manufactured product is state of the art The materials used were meticulously selected and are constantl...

Page 32: ...hanged colour or other aspects due to ther mal stress Improper transport and or incorrect storage Improper handling of fragile components such as glass and ceramics Improper handling and or use Lack o...

Page 33: ...rranty claims arising in a particular case 8 10 NOTE Your specialist dealer contractor will gladly advise and assist you in matters not covered by our warranty terms and conditions and undertakings We...

Page 34: ...GB 34 NOTES...

Page 35: ...GB GB GB 35...

Page 36: ...ndial para su sal n Het merk van wereldformaat voor uw woonkamer wiatowa marka do Pa stwa salonu 1 D Ihr Fachh ndler UK Your specialist dealer F Votre revendeur sp cialis IT Il vostro rivenditore spec...

Reviews: