20
Please contact your dealer who offers suitable parts for air inlet ducts
(pipes and damper).
Make sure that the wire mesh is mounted at the combustion air inlet.
3. INSTALLATION PLANNING
Clean all ashes out of the inside of the existing fireplace opening. Make
sure that the chimney and fireplace are free of cracks, loose mortar,
creosote deposits, blockage or other signs of deterioration. If necessary,
have any repair work done by a qualified professional before installing the
module.
Do NOT remove bricks or mortar from the fireplace. In case of an outside
air inlet or ash dump, fill with fiberglass insulation. Adhere to minimum
clearances as illustrated.
WARNING
WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION. CAREFULLY FOL-
LOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS
NEEDED TO INSTALL THE APPLIANCE. FAILURE TO DO SO MAY RESULT IN
A FIRE, ESPECIALLY IF COMBUSTIBLES ARE TOO CLOSE TO THE APPLI-
ANCE OR CHIMNEY AND AIR SPACES ARE BLOCKED, PREVENTING THE FREE
MOVEMENT OF COOLING AIR. DO NOT DRAW OUTSIDE AIR FROM GARAGE
SPACES. EXHAUST PRODUCTS OF GASOLINE ENGINES ARE HAZARDOUS.
DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN
FROM ATTIC SPACES, BASEMENTS OR ABOVE THE ROOFING WHERE OTHER
HEATING APPLIANCES OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR.
THESE PRECAUTIONS WILL REDUCE THE POSSIBILITY OF APPLIANCE SMOK-
ING OR AIR FLOW REVERSAL. THE OUTSIDE AIR INLET MUST REMAIN CLEAR
OF LEAVES, DEBRIS ICE AND/OR SNOW OR ANY OTHER OBSTACLES. IT
MUST BE UNRESTRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM
AIR STARVATION WHICH CAN CAUSE SMOKE SPILLAGE AND AN INABIL-
ITY TO MAINTAIN A FIRE. SMOKE SPILLAGE CAN ALSO SET OFF SMOKE
ALARMS. NEGATIVE PRESSURE WITHIN YOUR HOME MAY INADVERTENTLY
AFFECT YOUR APPLIANCE. TO PREVENT CONTACT WITH SAGGING OR LOOSE
INSULATION, THE APPLIANCE MUST NOT BE INSTALLED AGAINST VAPOUR
BARRIERS OR EXPOSED INSULATION. LOCALIZED OVERHEATING COULD
OCCUR AND A FIRE COULD RESULT. DO NOT USE MAKESHIFT COMPRO-
MISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT AIR, GRILLE
OR LOUVRE OPENINGS. DO NOT ADD A HOOD. KEEP HAND TOOLS IN GOOD
CONDITION; SHARPEN CUTTING EDGES AND MAKE SURE TOOL HANDLES
ARE SECURE. ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED TO
THE ENCLOSURE TO PREVENT FIRES. DO NOT PACK REQUIRED AIR SPACES
WITH INSULATION OR OTHER MATERIALS. COMBUSTION AIR INLET DUCTS
ARE NOT TO TERMINATE IN ATTIC SPACES OR CRAWL SPACES.
3.1 MINIMUM CLEARANCES TO COMBUSTIBLES
DO NOT PLACE ANY COMBUSTIBLE MATERIALS (FURNITURE,
FIREWOOD, ETC.) WITHIN 48”(1220mm) IN FRONT AND ON THE SIDES OF
THE Module.
COMBUSTIBLE MATERIALS CAN’T PROTRUDE ONTO THE METAL PARTS OF
THE UNIT, THEY MUST BE COVERED WITH NON COMBUSTIBLE MATERIALS.
PLEASE NOTE- 1/2” SPACERS ON THE SIDES AND AT THE BACK.
PLEASE KEEP THE 1/2 “ SPACES CLEAR OF INSTALLATION MATERIAL.