2" (min)
2" (min.)
fireplace
non combustible material
meterial sheet not included
4. INSTALLATION
4.1 HEARTH EXTENSION
WARNING
INSTALL THE HEARTH EXTENSION ONLY AS ILLUSTRATED!
A 20” (500mm) minimum hearth extension in front of the stove made of
non combustible material is required.In front of the unit, the hearth exten-
sion must extend 6’’ on each side. Also there must an hearth extension
under the unit, which extend 2” on the rear side. If there is a rear pipe,
under this pipe there must be an hearth extension too.
The non combustible material that is used must be UL 1618.
4.1.1 S 600
clearances
A
USA 16” / 406mm
Canada 18” / 457mm
B
8” / 203mm