36
In Canada: Install flexible stainless steel liner from the top of the chimney to
the module flue collar. Attach a stainless steel liner connector or elbow to the
liner and module onto the flue collar. Fasten with three screws. Secure the top
of the liner to the chimney cap using a liner support and chimney flashing. Cap
the top of the chimney liner assembly using an approved rain cap.
IIn the United States: While it is not required, it is recommended that a
chimney liner be installed that is continuous from the module to the top of
the chimney, particularly when the module is installed in a basement. For
this type of connection, use the “In Canada” installation instructions above.
If a continuous liner is not installed, a “direct flue connection” must be
made. The direct flue connection requires a non-combustible connector
that extends from the module into the chimney flue liner and also that the
installed flue cover be sealed below the entry point of the connector to
prevent dilution of combustion products in the chimney flue with air from
inside the house. Cap the top of the chimney using an approved rain cap.
4.5 FACTORY BUILT FIREPLACE
The ZERO CLEARANCE shall not be installed in a factory - built fireplace
system
floor protector
listed chimney liner
masonry chimney
must have
structural
integrity
follow manufactures´s
instructions for maximum
liner extension above
chimney
connector
rain cap
damper plate
removed or
fastened in open
position
flue cover (seal) with
non-combustible
material