- 43 -
Fig. 5b
Varia 1V H
2
O
Varia 1Vh H
2
O
- 44 -
Possible variant for incorporating the Varia 1V H
2
O and Varia 1Vh H
2
O in
a heating system (Fig. 5b).
A
3/8“ bleed valve
B
temperature sensor for the ½” overheat discharge valve
C
temperature sensor for the ½” thermostat switch
D
safety valve - 3 bar
E return
F
pump thermostat switch (eg. JUMO, heatTHERM)
G return
H
load unit fittings (e.g. ESBE; type LTC 141)
I circulating
pump
J
filling and drain fittings
K expansion
tank
L
safety fittings for the overheat discharge valve (e.g. SYR 3065)
M discharge
N ¾”
return
O
discharge from ½” overheat discharge valve
P
supply to ½” overheat discharge valve
Q ¾”
feed
R heating
system
connection
S load
unit