- 45 -
Fig. 5c
Varia 1V H
2
O XL
Varia 1Vh H
2
O XL
Varia 1V H
2
O XXL
Varia 1Vh H
2
O XXL
- 46 -
Possible variant for incorporating the Varia 1V H
2
O XL, Varia 1Vh H
2
O XL,
Varia 1V H
2
O XXL and Varia 1Vh H
2
O XXL into a heating system (Fig.
5c).
A
temperature sensor for the ½“ overheat discharge valve
B
temperature sensor for the ½” thermostat switch
C
safety valve - 3 bar
D bleed
valve
E
pump thermostat switch (eg. JUMO, heatTHERM)
F return
G
load unit fittings (e.g. ESBE; type LTC 141)
H circulating
pump
I
filling and drain fittings
J expansion
tank
K discharge
L
safety fittings for the overheat discharge valve (e.g. SYR 3065)
M ½”
return
N
discharge from ½” overheat discharge valve
O
supply to ½” overheat discharge valve
P
3/8” bleed valve
Q
1 ½” feed
R heating
system
connection
S load
unit
Summary of Contents for Mini Z1 H2O