- 7 -
1.2. Specification
Mini Z1
H
2
O
Mini Z1
H
2
O
XL
Varia 1V H
2
O
Varia 1V H
2
O
XL
Varia 1V H
2
O
XXL
Varia 2L
/2R
H
2
O
Varia
Ah H
2
O
Varia
A-FDh H
2
O
Unit
permissible
working
overpressure
3,0 bar
Max. permissible
feed tempera-
ture
1
105 °C
Max. operating
temperature
95 °C
Minimum feed
temperature.
62 °C
Minimum return
temperature
50 >80
>60
°C
Water flow
resistance
at 20 K
temperature
difference between
feed and return
at 10 K
temperature
difference between
feed and return
at 5 K
temperature
difference between
feed and return
ap-
prox.
7
18
29
ap-
prox.
7
18
29
ap-
prox.
3
8
30
ap-
prox.
9
20
30
ap-
prox.
9
20
30
ap-
prox.
12
21
34
ap-
prox.
15
32
47
ap-
prox.
15
32
47
mbar
Minimum heating
water flow rate
500 800 900 950 950 900 800 800 l/h
Minimum flow
rate for overheat
disharge valve
900 l/h
Water
capacity 25 25 16 46 46 41 32 32 L
- 8 -
Mini Z1
H
2
O
Mini Z1
/Z1
h
H
2
O XL
Varia 1V/1Vh
H
2
O
Varia 1V/1Vh
H
2
O XL
Varia 1V/1Vh
H
2
O XXL
Varia 2L
h
/
2Rh
H
2
O
Varia
Ah H
2
O
Varia
A-FDh H
2
O
Unit
Weight (empty,
without
accessories)
235 235 245 330 350 380 395 396 kg
Nominal output
range
4,9
–
9,1
7
–
13
7,7
–
14,3
10
–
18,7
14,8
–
27,5
10,3
–
19
7,3
–
13,5
7,3
–
13,5
kW
Nominal heat
output
7,0
11,0 14,4 21,2 14,7 10,4 10,4 kW
Quantity of wood
added per hour
2 2,9 3,7 4,2 5,8 5,7 2,8 2,8 kg/h
Water heating
5,5
8,0
5,5
10,0 15,5 8,4 7,7 7,3 kW
Proportion of
water *
78 80 50 69 73 58 74 70 %
Average flue gas
temperature *
235 245 280 207 173 264 210 210 °C
Minimum
required
manometric
pressure **
12 Pa
Flue gas mass flow
6 7,5 9,6
15,0
19,0
12,2 8 12,2 g/s
Feed connection
¾
¾
¾
1 ½
1 ½
1
¾
¾
“IG
Return
connection
¾
¾
¾
1 ½
1 ½
1
¾
¾
“IG
Safety heat
exchanger –
supply pipe
½“
IG
½“
AG
½“
AG
½“
AG
½“
AG
½“
AG
½“
½“
–
Safety heat
exchanger -
discharge
½“
IG
½“
AG
½“
AG
½“
AG
½“
AG
½“
AG
½“
AG
½“
AG
–
1
The overheat discharge valve incorporated in the heating system will
open the cold water feed at a flow temperature of approx. 95°C
.
* The values shown represent the mean over a combustion period. These values apply
under test conditions at nominal heat output, burning approx. 2.9 kg dry beech wood
per
hour
.
** Higher draughts should be reduced to less than 30 Pa by appropriate measures, such as a
secondary air device or air regulator.
10,0
Summary of Contents for Mini Z1 H2O
Page 5: ...9 Mini Z1 H2O Fig 1a 10 Mini Z1 H2O XL Fig 1b...
Page 6: ...11 Mini Z1h H2O XL Fig 1c 12 Varia 1V H2O Fig 1d...
Page 7: ...13 Varia 1Vh H2O Fig 1e 14 Varia 1V H2O XL Fig 1f...
Page 8: ...15 Varia 1Vh H2O XL Fig 1g 16 Varia 1V H2O XXL Fig 1h...
Page 9: ...17 Varia 1Vh H2O XXL Fig 1i 18 Varia 2Lh 2Rh H2O Fig 1j...