frequent burn-down to the basic embers should be avoided.
• Double glazing (IR reflective surface): Through application of oxidic
coatings on the glass surface, infrared spectral components from the
combustion chamber are reflected to a great extent. These coatings
generate the interference colours (similar to a rainbow), the so-called IR
reflective surface. Through this colouration, the quality characteristic of
the „IR reflective surface“ is visible, i.e. recognisable. This colouration
cannot be removed.
• To operate the stove with nominal heat output, the following prerequisites
are necessary.
- Combustion must be operated with a closed door.
- Chimney draught: 12 Pa
- Negative pressures greater than 20-25 Pa can influence correct
operation. In this regard, contamination of the view pane can increase
or noise can be intensified!
- Wood:
Dry beech wood (moisture < 18%)
- Wood feed quantity:
3.7 kg; distributed over three similar logs.
- Air setting:
1/4 opened, may need to be slightly
adapted depending on local conditions
(see example). During the combustion
phase the air lever can be opened for
several minutes.
- At a combustion time of approx. 70 minutes the provided output of the
fireplace insert that is given off is approx. 10 kW.
3. INITIAL COMMISSIONING
Heat generation systems must only be produced and installed by specialised
companies. The initial commissioning must only be executed by an expert
employee of the installation company. A certificate confirming proper
installation and proper adjustment / function of all control components and
safety components must be given to the owner / operator of the system.
Moreover, the operator must be instructed in detail concerning the operation,
function and maintenance of the overall system, including all supplemental
components. In addition, the measures for maintaining safe operation of
the system must be communicated to the operator. Execution of instruction
must be documented in the commissioning protocol! The installation and
operating manual must always be kept in good condition in the vicinity of
the Nova F, where it can be easily accessed.
4. OPERATION
For operation, also comply with the instructions in the operating manual
of the fireplace inserts. The instructions in this installation and operating
manual refer to special operation of a heating insert, such as the Nova F.
• The fireplace insert locking door must always be operated with a
self-closing door. This means that the combustion chamber door is gen-
erally closed. The door may only be opened to put on more firewood or
for cleaning when in a cool state. Manipulation of the closing device is
prohibited.
• The distance between flammable parts/furniture and the view pane must
be at least 80 cm!
• The fireplace insert is designed for the burning of dry, untreated wood
logs with adhering bark and wood briquettes.
• Heat exchanger deflected. If the flue gas temperature drops under this
temperature again, the flue gas damper opens. For better efficacy of the
heat exchanger, the Nova F should be fired as uniformly as possible, and
Example of wood placement with air
adjustment