GB
4
The fireplace can be operated manually or with suitable combustion control-
lers and appropriate settings. If necessary, consult with Spartherm Feu-
erungstechnik GmbH in this regard.
1.1 SCOPE OF DELIVERY
Nova F tested in accordance with DIN EN 13229 WA with the following
features:
• Tiled stove with chamotte lining and hinged door.
• Carrying aids
• Flue gas outlet
• Combustion air duct
• Materials that come into contact with fire made of temperature-resistant
steel to 1200°C; material 1.4841
• Support bearing
The following components are available as options:
• S-Thermatik, combustion controller with temperature display for buffer
tank temperature · Coasting temperature unit (heat recovery section)
1. GENERAL INSTRUCTIONS
Prior to setup and installation of the tiled stove system, Nova F, a discussion
must be conducted with your responsible district master chimney sweep. He
will advise you of building law regulations, the suitability of your chimney,
and will execute the acceptance procedure of your tiled stove. The chimney
calculation is executed in accordance with DIN EN 13384 with the value
triplet specified in this manual (see technical data).
OUR HEATING INSERT HAS BEEN TESTED IN ACCORDANCE WITH
DIN EN 13229 AND SATISFIES THE REQUIREMENTS STIPULATED
IN THE CONSTRUCTION PRODUCTS DIRECTIVE. (DECLARATION OF
PERFORMANCE IS AVAILABLE AND CAN BE VIEWED AT
WWW.SPARTHERM.COM)
Small children, elderly or infirm persons: As is the case with all heat-
ing devices, it is expedient that you attach a protective fixture for these
groups of persons, as the view pane and also the cladding parts can
become extremely hot! Danger of burn injuries! Never leave these groups
of persons unattended near the fireplace when a fire is burning or has
just been extinguished! National and European standards, the respective
state-specific and local directives and regulations, in particular the
respective firing installation ordinance of the German Federal State, must
be complied with for the setup and operation of your fireplace insert and for
the connection to the chimney
The fireplace must always be operated with a self-closing door. Modification
of the closing device is prohibited! Coasting temperature surfaces can be
integrated in the connecting line to the chimney. These downstream heating
surfaces must only reduce the flue gas temperature to the extent possible
for safe and suitable operation of the flue gas system!