3.6.3 FIRE PROTECTION/MINIMUM DISTANCES DUR-
ING THE SET-UP OF FURNITURE
When installing a bespoke furniture unit against a wall, a minimum distance
of 50 mm from that wall, i.e. behind the unit, must be maintained, and to
either side. The reference point is the installation frame of the Quadra Inside
housing (see Figs. 13 to 24).
Quadra Inside I SL
• In order to guarantee sufficient thermal insulation, there must be a
minimum distance of 1000 mm (see Fig. 16) to flammable components,
furniture, decorations and curtains at the side! There must be no objects
between the ebios-fire furniture item and the room ceiling (distance to
the ceiling >1000 mm) (see Fig. 15)!
min.
1000 (distance from ceiling)
Fig. 15 Minimum distance from ceiling
Fig. 14 Minimum distances in a room corner
min.
min.
Fig. 16 Minimum distances from combustible components
min.
min.
min.
Fig. 13 Minimum distances to wall
min. 50
min.