GB
GB
23
3.7.1.3 QUADRA INSIDE III SL
• The width of the fireplace insert measures at least 1760 mm.
• The height of the fireplace insert measures at least 350 mm.
• The depth of the fireplace insert is defined as 400 mm.
• The distance from front edge of housing area to housing frame is defined
as 50 mm.
• The cutaway in the base of the combustion chamber (support panel for
the Quadra Inside III) measures 1701 x 223 mm.
• The minimum distance between housing and housing area base meas-
ures 70 mm.
• The minimum width of housing area measures 1760 mm.
• The minimum depth of housing area measures 360 mm.
• The free cross-section for the additional air aperture in the hous-
ing area measures at least 600 cm².
• The combustion chamber is made of vermiculite slabs or ob calcium
silicate slabs with a material thickness of at least 40 mm. These materi-
als must be approved by the German Institute of Building Technology in
Berlin (DIBt), i.e. must hold verification of suitability for use as combus-
tion chamber linings.
• The thermal insulation to be used includes mats, slabs or pipe sections
of silica-based insulation material (stone or slag and ceramic fibres) of
material class A1 as per DIN 4102, part 1 with an upper application limit
temperature of at least 700°C when measured as per DIN 52271 and
a rated gross density of 80 kg/m³. When using insulating materials of
this type, ensure they are provided with an AGI-Q 132 code number (the
indication of thermal insulation thickness (Fig. 30) also refers to mineral
wool, as defined in AGI Q 132).
• Ensure that additional air can flow into the housing area without obstruc-
tion. Free minimum cross section for additional air is 600 cm². To this
end, appropriate inlet apertures must be provided.
• The Quadra Inside III must be bolted to the support panel with 6 appro-
priate screws.
1
Firebox
5
Vermiculite or calcium silicate slab
t
≥
40 mm
2
Housing area
6
Mineral wool insulation
(in acc. with AGI-Q 132) t
≥
60 mm
3
Quadra Inside III SL
7
External cladding
4
Additional air aperture
Free cross section, min. 600 cm²
Fig. 30 Minimum distances from fire area
min.
min.
min.
min.
min.