background image

GB

 4

IMPORTANT INFORMATION

As per the German Equipment and Product Safety Act (GPSG) and our statutory duty to notify, we would like to inform you about heating with this product.

As per our statutory duty to notify, we would like to inform you about heating with this product: The Bio chimney combustion heat with:

•  Quadra Inside I SL – 0.5 l / hr amounts to approx. 3300 Watts
•  Quadra Inside II SL – 1.0 l / hr amounts to approx. 6600 Watts
•  Quadra Inside III SL – 1.5 l / hrs measures approx. 9900 Watts

The calorific value of 96.6% ethanol equates to approx. 29,600 kJ / kg. With fuel consumption in the:

•   Quadra Inside I SL (0.5 l/hr approx. 0.4 kg/hr) 

= heat released approx. 3300 Watts

•  Quadra Inside II SL (1.0 l/hr approx. 0.8 kg/hr 

= heat released approx. 6600 Watts

•  Quadra Inside III SL (1.5 l/hr approx. 0.8 kg/hr 

= heat released approx. 9900 Watts

However, the decorative fireplace requires a plentiful supply of fresh air when operated as otherwise the amount of carbon dioxide created exceeds the permitted 
concentration in the room air. 

As a rule, the fresh air supplied is cooler than the room air to be heated up which results in a loss of energy. The effective heat output of a biofuel fireplace is thus 
minimal and, as such, decorative fireplaces which use biofuel are not sources of heat.

This is a decorative fireplace that is not intended for heating or continuous operation. Nevertheless, it should be taken into account that heat is generated as a 
by-product of the combustion process. This can cause increased heating in the room where the fireplace is installed. Read the safety instructions and measures for 
rear ventilation carefully.

Observe these operating instructions.

Summary of Contents for Quadra Inside I SL

Page 1: ...Installation and Operating Manual ebios fire Quadra Inside I II III SL...

Page 2: ...ffer you first class products that will touch your customers emotionally and will inspire feelings such as a feeling of security safety and comfort To achieve this we recommend that you read the opera...

Page 3: ...3 Quadra Inside III SL 23 3 8 Fire protection minimum distances for fire areas created by craftsmen 24 3 8 1 Quadra Inside I SL 24 3 8 2 Quadra Inside II SL 24 3 8 3 Quadra Inside III SL 24 3 9 Combu...

Page 4: ...x 6600 Watts Quadra Inside III SL 1 5 l hr approx 0 8 kg hr heat released approx 9900 Watts However the decorative fireplace requires a plentiful supply of fresh air when operated as otherwise the amo...

Page 5: ...at the commissioning stage on this subject refer to 4 Safety assessment All models may only be operated with the closed housing cover Please note that fuel must not be refilled while the appliance is...

Page 6: ...Quadra Inside I SL Item Designation Pos Designation A Housing H Filling opening B Burner fleece I Cold Hand C Burner channel K Key tank seal D Cover plate L Bottle for wetting the burner E Stick light...

Page 7: ...Oldenbourg Verlag Please note that the luminosity of the flame can decrease to such an extent that the flame is no longer clearly visible Make your children and others in the home aware of this These...

Page 8: ...urg Verlag Please note that the luminosity of the flame can decrease to such an extent that the flame is no longer clearly visible Make your children and others in the home aware of this These details...

Page 9: ...bourg Verlag Please note that the luminosity of the flame can decrease to such an extent that the flame is no longer clearly visible Make your children and others in the home aware of this These detai...

Page 10: ...ural conditions and type of use The floor area of the installation must be of a design and size such that the ebios fire can be operated properly and as intended Only permitted and sufficiently strong...

Page 11: ...ign modifications whatsoever are permitted to the design of the Quadra Inside SL models 3 6 GENERAL NOTES FOR INSTALLATION IN BESPOKE FURNITURE ITEMS In all cases involving bespoke furniture design fo...

Page 12: ...storage area Storage area and housing area must be sepa rated by a partition floor panel and a back wall 1 Quadra Inside SL 5 Wall mounting 2 Cover plate table top 6 Rear ventilation 3 Housing room 7...

Page 13: ...must be provided 3 6 1 2 QUADRA INSIDE II SL The minimum dimension of the cover plate table top Fig 6 measures at least 1250 x 400 mm width x depth The cutaway for the Quadra Inside II SL measures 11...

Page 14: ...dimension of cover plate table top Fig 8 measures at least 1751 x 400 mm width x depth The cutaway for the Quadra Inside III SL measures 1701 x 223 mm and is cut centrally into the cover plate table...

Page 15: ...ise the housing cover can become covered in soot and the flames may no longer be uniform in appearance Quadra Inside I SL Then the 4 protective panes are installed Quadra Inside II SL Then the 6 prote...

Page 16: ...e I SL In order to guarantee sufficient thermal insulation there must be a minimum distance of 1000 mm see Fig 16 to flammable components furniture decorations and curtains at the side There must be n...

Page 17: ...ations and curtains at the side There must be no objects between the ebios fire furniture and room ceiling distance to the ceiling 1000 mm see Fig 19 Fig 17 Minimum distances from wall min min Fig 18...

Page 18: ...niture decorations and curtains There must be no objects between the ebios fire furniture and the room ceiling distance to the ceiling 1000 mm see Fig 23 Fig 22 Minimum distances in a room corner Fig...

Page 19: ...ross section at the free aperture for additional air in a furniture unit measures Quadra Inside I SL 200 cm Quadra Inside II SL 400 cm Quadra Inside III SL 600 cm The rear ventilation features must be...

Page 20: ...t B Corner variant left C Corner variant right D Three sided open variant E Transparent variant Variants of open fireplace inserts Quadra Inside III SL Variants of open fireplace inserts A Front varia...

Page 21: ...g Tech nology in Berlin DIBt to verify their suitability for use as combustion chamber lining The thermal insulation to be used comprises mats slabs or pipe sections of silica based insulation materia...

Page 22: ...bility for use as housing area linings The thermal insulation to be used comprises mats slabs or pipe sections of silica based insulation material stone or slag and ceramic fibres of material class A1...

Page 23: ...suitability for use as combus tion chamber linings The thermal insulation to be used includes mats slabs or pipe sections of silica based insulation material stone or slag and ceramic fibres of mater...

Page 24: ...esh air to the room in which the fire is installed It is possible that there is not a sufficient supply of fresh air if the windows and doors are sealed e g in combination with energy saving measures...

Page 25: ...ildren elderly or infirm persons As is the case with all open flames it is expedient that you attach a protective fixture for these groups of persons available as an accessory from specialist dealers...

Page 26: ...illed via the burner channel DANGER TO LIFE The handling of fuel in the vicinity of the hot or burning appliance is associated with significant risks and is not permitted Only fill the burner via the...

Page 27: ...ely for combustion and it not suit able for consumption Supervise your children If swallowed consult a doctor immediately and present the fuel label 4 4 COMMISSIONING The ebios fire Quadra Inside is s...

Page 28: ...ead maintains a uniform distance from the burner channel Then insert the protective panes 12 Insert the cold hand to grip the cover plate and lift it off 13 Wet the burner fleece with fuel using the b...

Page 29: ...the housing cover Depending on the installation situation the protective panes may need to be removed When being installed in a bespoke fire area chimney system the burner should be filled outside the...

Page 30: ...the room and on the furnishings where the fire is installed 6 MAINTENANCE TROUBLESHOOTING The wick and burner fleece must be visually inspected at regular inter vals The material can be easily damage...

Page 31: ...s apply for the contractual relationship between the manufacturer Spartherm Feuerungstechnik GmbH and the dealer distributor They are not congruent with the contractual and warranty terms which the de...

Page 32: ...reless handling of fragile components such as glass or ceramics improper operation and or use incorrect filling of system lack of maintenance incorrect set up installation of device failure to comply...

Page 33: ...respect of statutory legal requirements 7 10 CLOSING REMARKS In addition to these warranty conditions and our commitment to them our dealers and contractual partners are pledged to assist you in both...

Page 34: ...rom being classified in accordance with applicable legislation on standards Unlike with the Quadra Inside I SL the models Quadra Inside II SL III SL are not covered by the DIN 4734 1 standard and cann...

Page 35: ...GB GB 35 NOTES...

Page 36: ...merk van wereldformaat voor uw woonkamer wiatowa marka do Pa stwa salonu 1 D Ihr Fachh ndler UK Your specialist dealer F Votre revendeur sp cialis IT Il vostro rivenditore specializzato E Sus comerci...

Reviews: