6.3. SETTING THE RADIO FREQUENCY
It may be advisable to alter the transmission frequency via DIP switches in
certain circumstances (e.g., if several remote controls all transmitting in the
434 MHz range are in use). Proceed as follows to set the frequency:
1. Turn off the power to the control unit for at least 30 seconds (remove
mains plug).
2. Remove remote control battery compartment cover.
3. Use a pointed implement to set the DIP switches as required.
4. Close the battery compartment cover.
5. Turn the power to the control unit back on.
6. Press any button on the remote control to transmit the new frequency
to the control unit. Hold down the button for about 5 seconds when
doing this.
7. The control unit acknowledges the change with a short audible signal.
7. CLEANING
Clean the convection inlet slots in the fireplace covering, the blower intake
aperture and the hot-air ducts at regular intervals before and during the
heating season. Deposits (dust, etc.) may make the room dirty.
8. USER GUIDE
Problem
Solution
The operating status
display
on the control unit
does not light up.
• Switch on at main switch or insert plug into socket.
Or call in a specialist:
• Check the fine-wire fuse and replace if necessary (F2A / 250V).
Control unit does
not
respond to commands from
the remote control.
• Replace remote control battery (LED on remote control must light up
when button is pressed).
• Switch on at main switch or insert plug into socket. The red operating
status display on the control unit
must
light up).
• Set the correct radio frequency.
The blower does
not
start in
Automatic mode.
• Switch on at main switch or insert plug into socket. The red LED must
light up.
• Check switch-on temperature and reduce it if necessary.
Or call in a specialist:
• Check temperature sensor connections.
• Check temperature sensor and replace if necessary.
Blower does
not
start up, or
it shuts down after a time.
But the operating status
display is lit.
• Blower safety shutdown because of the temperature.
• Remove deposits from air grille, apertures and blower.
B l o w e r s t a r t s u p
automatically in
Manual
mod
• Convection air housing temperature is higher than 105°C (see Section
„5.2.1. Manual Mode“)
For other problems please contact your stove installer. Only manufacturer’s