GB
GB
9
Press the
button to cycle through the blower speeds.
Button
Audible Signal
Blower
first press
one short
Stage 1
second press
two short
Stage 2
third press
three short
Stage 3
fourth press
two short
Stage 2
fifth press
one short
Stage 1
sixth press
one
long
off
The next time the
button is pressed, the blower will start up again on
Stage 1.
Note:
Even in manual mode, the blower will switch on automatically when
the sensor temperature reaches approx. 105°C (switch-off temperature
approx. 100°C). This function cannot be disabled. Its purpose is to prevent
overheating of the convection air housing.
5.2.2. AUTOMATIC MODE
Description: In this mode, when the switch-on temperature is reached the
blower runs automatically at the preset speed. The speed can be adjusted
via the
button (as in Manual mode). The blower switches off again
when the temperature falls below the switch-on temperature.
Pressing the
AUT (orange)
button on the remote control enables Automatic
mode. This is acknowledged by the control unit with a ‘long audible signal’.
The switch-on temperature is factory-set to approx. 45°C. See Section „6.2.
Setting the Switch-on Temperature“.
5.2.1. MANUAL MODE
Description: In this mode the operator selects the blower speed via the
remote control. The integral temperature sensor is not active. The desired
blower speed can be selected via the
button.
Pressing the MAN (blue) button on the remote control enables Manual mode.
This is acknowledged by the control unit with a ‘long audible signal’.
LED
Automatic
mode
Manual
mode
Speed selector
switch
Proportional mode