10
630359_5
2.7 SPECIFICATIONS TABLE
Product
Type
Flue
Damper
Separate
Frame
Required
Fixed or
variable
Aeration
Average
Min
power*
(kW)
Average
Peak power*
(kW)
Average
Efficiency**
(%)
Flue
diameter
(mm)
Average
Emission
factor
(g/kg)
Unit
weight
(Kgs)
Single XL (Varia Bh-
P7)
Lift Door
Yes
Yes
Fixed
N/A
16.0
65.3
200
0.92
398
Single Large Lift
Door (Varia ASh-P8)
Lift Door
Yes
Yes
Variable
8.3
14.1
67.6
150
0.99
264
Double Sided
(Varia A-FDh-P8)
1 Swing Door
1 Lift Door
Yes
Yes – one
side only
Variable
15.5
19.6
65.6
200
1.41
365
Corner L/H
(Varia 2L 80h-P7)
Lift Door
Yes
Yes
Fixed
N/A
14.5
65.9
150
0.96
312
Corner R/H
(Varia 2R 80h-P7)
Lift Door
Yes
Yes
Fixed
N/A
14.5
65.9
150
0.96
312
* Dependent on fuel loading
** Tested in accordance with AS/NZS 4012:2014 and dependent on fuel loading