12
630359_5
The wood burning appliance and chimney vent system also
requires a sufficient supply of combustion air not only to
support the combustion in the combustion chamber but to
replace the exhaust leaving it so it can flow freely up through
the vent system and out into the atmosphere. It is the correct
balance of combustion air and the chimney vent system that
will ensure the appliance provides you with its optimum
performance.
Be sure to provide sufficient combustion air when taking
combustion air internally. There are many other appliances in
your home competing for air such as: a kitchen range hood,
forced air heating devices or a bathroom exhaust fan.
ENSURE THAT THE LIFT DOOR TRANSIT SCREW(S) ARE
REMOVED PRIOR TO CONSTRUCTING THE SKAMOTEC
ENCLOSURE AND ‘BOXING IN’ THE APPLIANCE.
WEAR GLOVES AND SAFETY GLASSES FOR
PROTECTION.
WEAR A SUITABLE RESPIRATOR MASK WHEN CUTTING
THE SKAMO ENCLOSURE BOARD.
CAREFULLY FOLLOW THE INSTRUCTIONS FOR
ASSEMBLY. FAILURE TO DO SO MAY RESULT IN A FIRE,
ESPECIALLY IF COMBUSTIBLES ARE TOO CLOSE TO
THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE
BLOCKED, PREVENTING THE FREE MOVEMENT OF
COOLING AIR.
DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES -
EXHAUST PRODUCTS OF GASOLINE ENGINES ARE
HAZARDOUS. DO NOT INSTALL OUTSIDE AIR DUCTS
SUCH THAT THE AIR MAY BE DRAWN FROM ATTIC
SPACES, BASEMENTS OR ABOVE THE ROOFING WHERE
OTHER HEATING APPLIANCES OR FANS AND CHIMNEYS
EXHAUST OR UTILIZE AIR. THESE PRECAUTIONS WILL
REDUCE THE POSSIBILITY OF APPLIANCE SMOKING OR
AIR FLOW REVERSAL. THE OUTSIDE AIR INLET MUST
REMAIN CLEAR OF LEAVES, DEBRIS, ICE AND/OR SNOW
OR ANY OTHER OBSTACLES. IT MUST BE
UNRESTRICTED WHILE APPLIANCE IS IN USE TO
PREVENT ROOM AIR STARVATION WHICH CAN CAUSE
SMOKE SPILLAGE AND AN INABILITY TO MAINTAIN A
FIRE. SMOKE SPILLAGE CAN ALSO SET OFF SMOKE
ALARMS.
NEGATIVE PRESSURE WITHIN YOUR HOME MAY
INADVERTENTLY AFFECT YOUR APPLIANCE.
DO NOT USE MAKESHIFT COMPROMISES DURING
INSTALLATION. DO NOT BLOCK OR RESTRICT AIR,
GRILLE OR LOUVRE OPENINGS.
ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED
TO THE ENCLOSURE TO PREVENT FIRES.
DO NOT PACK REQUIRED AIR SPACES WITH
INSULATION OR OTHER MATERIALS.
Summary of Contents for Varia 2L 80h-P7
Page 5: ...5 630359_5 2 0 PRODUCT DIMENSIONS 2 1 2 2 Figure 1 Figure 2 ...
Page 6: ...6 630359_5 2 3 Figure 3 ...
Page 7: ...7 630359_5 2 4 Figure 4 ...
Page 8: ...8 630359_5 2 5 Figure 5 ...
Page 23: ...23 630359_5 Corner L R Varia 2L 2R 80h P7 Double Sided Varia A FDh P8 Figure 23 Figure 24 ...
Page 26: ...26 630359_5 3 7 EXAMPLE OF CAVITY CONSTRUCTION Figure 30 Figure 31 ...
Page 51: ...51 630359_5 ...
Page 52: ...52 630359_5 Data Plate Installer Adhere duplicate data plate here ...