20
630359_5
Outside the confines of the cavity, the aluminium ducting
should be run and completely housed within a box cavity
construction made
entirely from
skamo enclosure board. Do
not use any combustible materials within this boxing.
Wherever the discharge air vent is located in a wall other than
the fireplace cavity (constructed from skamo enclosure
board), the wall facing material immediately surrounding the
discharge air vent must be constructed of a heat resistive
insulating material such as Promina or Eterpan board (min
10mm thick). Any wall support elements/structure made of
combustible materials immediately adjacent the vent should
be protected from heat by the use of skamo enclosure board
sheets as shown:
The discharge vent must be no closer than 400mm to a
heat sensitive ceiling or overhead projection.
Escea accepts no liability for improper installation or
consequential damages.
PROVISION MUST ALWAYS BE MADE FOR RETURN AIR
FROM HEATED ROOMS E.G. UNDERCUT DOORS, VENTS
OR NATURAL LEAKAGE.
WARNING: OVERHEATED ROOMS OR AREAS ARE NOT
SAFE FOR INFANTS!
3.5 SAFETY CLEARANCES
All safety clearance dimensions stated are minimum
requirements.
Combustible
frame
Skamotec
sheets
Discharge
Vent
Eterpan/Promina
board. Min
distance 300mm
all around.
Discharge
Vent
Figure 18
Figure 17
Summary of Contents for Varia 2L 80h-P7
Page 5: ...5 630359_5 2 0 PRODUCT DIMENSIONS 2 1 2 2 Figure 1 Figure 2 ...
Page 6: ...6 630359_5 2 3 Figure 3 ...
Page 7: ...7 630359_5 2 4 Figure 4 ...
Page 8: ...8 630359_5 2 5 Figure 5 ...
Page 23: ...23 630359_5 Corner L R Varia 2L 2R 80h P7 Double Sided Varia A FDh P8 Figure 23 Figure 24 ...
Page 26: ...26 630359_5 3 7 EXAMPLE OF CAVITY CONSTRUCTION Figure 30 Figure 31 ...
Page 51: ...51 630359_5 ...
Page 52: ...52 630359_5 Data Plate Installer Adhere duplicate data plate here ...