WEAR SUITABLE GLOVES TO OPERATE YOUR
APPLIANCE.
NEVER OPERATE THE FIRE WITH THE GRATE COVER
REMOVED.
DO NOT POKE OR STIR THE LOGS WHILE THEY ARE
BURNING.
AVOID RISK OF BURNS. REMOVE OPERATIONAL TOOL
AFTER USE!!!
BRIEF CONTACT MAY CAUSE SKIN BURNS.
Your Spartherm product is designed with the most advanced
technology. The appliance is extremely airtight. It has an
exclusive direct outside air supply (optional kit); a safety
feature designed to prevent spillage, and to keep your house
free of carbon monoxide, in case of a down drafting chimney
or an internal negative pressure.
The first fire(s) in your appliance may be difficult to get going
and keep going with a lesser amount of heat being generated.
This is a result of the moisture being driven out of the fire
brick. Allow 30 hours of hot fires before your appliance will
perform optimally.
During the break-in period (the first 2 or 3 fires) create only
small, hot fires using kindling or small wood pieces; this will
allow the firebrick to cure.
Do not be alarmed if small hairline cracks develop in the
firebrick. This is a normal occurrence and does not pose a
safety hazard.
The paint may also smell for the first few fires as it cures and
it is recommended to open a door or window to alleviate the
smell.
Traditional Method of Lighting a Fire (Bottom Up)
To start, a brisk fire is required. Place loosely crumpled paper
on the floor of the appliance and cover with dry kindling. Open
the draft control fully (if available) by moving the lever to the
right. Fully open the flue damper if this is an option. Light the
paper and leave the door slightly ajar (25mm) until all kindling
is burning.
To maintain a brisk fire, a hot ember bed must be established
and maintained.
Slowly add slightly larger wood pieces. Lay the pieces
lengthwise from side to side in the hot ember bed with a small
gap between each piece so that the air can flow directly into
this gap and ignite the fuel above.
When the fire seems to be at its peak, medium/large sized
logs may be added. Once these logs have caught fire,
carefully close the door. Closing the door too quickly after
refuelling will reduce the firebox temperature and result in an
unsatisfactory burn.
Summary of Contents for Varia 2L 80h-P7
Page 5: ...5 630359_5 2 0 PRODUCT DIMENSIONS 2 1 2 2 Figure 1 Figure 2 ...
Page 6: ...6 630359_5 2 3 Figure 3 ...
Page 7: ...7 630359_5 2 4 Figure 4 ...
Page 8: ...8 630359_5 2 5 Figure 5 ...
Page 23: ...23 630359_5 Corner L R Varia 2L 2R 80h P7 Double Sided Varia A FDh P8 Figure 23 Figure 24 ...
Page 26: ...26 630359_5 3 7 EXAMPLE OF CAVITY CONSTRUCTION Figure 30 Figure 31 ...
Page 51: ...51 630359_5 ...
Page 52: ...52 630359_5 Data Plate Installer Adhere duplicate data plate here ...