40
630359_5
• The chimney connector and dampers as well as the chimney
should be cleaned.
• The appliance’s firebox and baffle system should be cleaned
if needed.
• The chimney should be inspected and repairs made if
needed.
• The chimney should be swept from above. Removal of the
vermiculite baffle(s) and steel baffle plate from within the
firebox will aid in access to vacuum the residue from below.
The flue damper should be set to fully open for this procedure.
5.7 DO’s and DON’Ts
DO
• Build a hot fire.
• Use only dry wood.
• Several pieces of medium sized wood are better than a few
big pieces.
• Refuel frequently using medium sized wood.
• Clean chimney regularly (at least once a year).
• “Fine Tune” the air settings (if available) for optimum
performance.
DON’T
• Take ash out immediately. Let it accumulate to a depth of at
least one inch. A good ash layer provides for a longer lasting
and better burning fire.
• Burn wet wood
• Close the door too soon or damper down too quickly.
• Burn one large log rather than two or three smaller, more
reasonably sized logs.
• Burn at continually “low setting”, if glass door is constantly
blackened. This means the firebox temperature is too low and
energy is wasted by incomplete combustion.
Summary of Contents for Varia 2L 80h-P7
Page 5: ...5 630359_5 2 0 PRODUCT DIMENSIONS 2 1 2 2 Figure 1 Figure 2 ...
Page 6: ...6 630359_5 2 3 Figure 3 ...
Page 7: ...7 630359_5 2 4 Figure 4 ...
Page 8: ...8 630359_5 2 5 Figure 5 ...
Page 23: ...23 630359_5 Corner L R Varia 2L 2R 80h P7 Double Sided Varia A FDh P8 Figure 23 Figure 24 ...
Page 26: ...26 630359_5 3 7 EXAMPLE OF CAVITY CONSTRUCTION Figure 30 Figure 31 ...
Page 51: ...51 630359_5 ...
Page 52: ...52 630359_5 Data Plate Installer Adhere duplicate data plate here ...