background image

Trouble analysis and obviation

Phenomenon

Reason

Solution

The water 

pump does 

not operate

1. The air switch is not tight, and leak
pressure.
2.Air switch are ineffective.
3.The plug not be inserted or power
supply abnormally.
4.There are sundries

that blocks the water pump impeller.

5.The water level not reached the height
stipulated.

1.Insert the air pipe closely.
2.Adjust the air switch.
3.Insert the plug closely.
4.Remove sundries.
5 . Add water to the
suitable height.

Can't adjust 

the massage 

strength

1. Power supply is abnormal.
2. The strength adjusting does not act.
3.The large air pipe not been inserted
closely.

1.Insert the plug closely.
2.Adjust the strength
adjusting.
3.Insert the air pipe
closely.

The water 

pipe leaks

1.Seal gasket is not good.
2.The nut not been locked tightly,
interface place sticking is bad.
3.The inner layer in the water pipe
breaks.

1.Change the seal ring.
2.Screw down the nut,
and seal the interface.

3.change the water tube.

The 

submarine

 light is not 

bright

1.The fuse of the light is melted.

2. No water in the bathtub or the

water not high enough.
3.The light bulb has been out of order.

1.Change the fuse with
specification.
2.Add water to be higher
than the nozzle.
3.Change the light bulb.

18

Summary of Contents for C654 S

Page 1: ...1 Ordernummer __________ Seriennummer __________ Wichtige Informationen...

Page 2: ...it entsprech ender Verkleidung versehen werden 6 Das Ger t kann von Kindern von mindestens 8 Jahren und von Personen mit eingeschr nkten k rperlichen und geistigen F higkeiten wie auch von Menschen mi...

Page 3: ...654 S USER MANUAL 155 x 155 x 83 cm Montage und Bedienungsanweisung Instructions for installation operation 3 Gewicht cGewicht 110 kga 120 kg Wasservolumen Minimum 400 Liter Wasservolumen Maximum 4 0...

Page 4: ...Trouble analysis and obviation Maintenance Instructions for use the control panel System install sketch Operation instructions HINWEISE ZUM AUFBAU BEDIENUNGSANLEITUNG INSTANDHALTUNG SICHERHEITSHINWEIS...

Page 5: ...aagerecht aus Legen Sie die Anschl sse f r Wasser Zoll Strom und Ab uss 1 Zoll gem der Skizzen Wenn Sie sichergestellt haben dass die Zuleitungen und Anschl sse korrekt verlegt sind k nnen siehe unten...

Page 6: ...Wasserablaufknopf knob 2 im Uhrzeigersinn f r nicht weiter als ca 45 Grad um das Ab ussventil anzuheben damit das Wasser aus der Badewanne ablaufen kann Drehen Sie entgegen dem Uhrzeigersinn um das Ve...

Page 7: ...das Ger t zuerst aus bevor Sie das Wasser ablaufen lassen um Wasserr ckstau in SICHERHEITSHINWEISE werden Wasserstand die Luftmassaged sen berstiegen hat k nnen Sie Luftd sen einschalten Lassen Sie zu...

Page 8: ...nel Input ANT Main box Water Sensor Bubble Bath Pump Speaker Lamp Heater Ozone Pump Computerpanel Stromanschluss Antenne Elektronikbox Wasserstandserkennung Luftpumpe Lautsprecher Beleuchtung Heizung...

Page 9: ...u pumpe Heizung Lautsprecher Beleuchtung Ozonreinigung Wasserstandser kennung Antenne MASSAGE BATHTUB CONTROLLER MODEL GD 7001BT VOLTAGE AC220 240V50 60HZ MAX TOTAL LOAD 14 2A WATERPROOFGRADE IPX4 SPE...

Page 10: ...er Ozone Set FM AUX LCD Anzeige Abw rts Aufw rts Beleuchtung Luftpumpe Wasserpumpe Ein Ausschalten Heizung zur Aktivierung 2 Sekunden gedr ckt halten Ozonreinigung zur Aktivierung 2 Sekunden gedr ckt...

Page 11: ...leuchten schaltet sich die Heizung ab weil die erforderlichen Voraussetzungen nicht erf llt sind 5 Beleuchtung 6 Ozonreinigung Nach 15 Minuten schalten sich die Ozonreinigung selbstst ndig aus Sie k n...

Page 12: ...ntsprechenden Kabel richtig angeschlossen sind Sollten Ozonreinigung und Beleuchtung nicht funktionieren berpr fen Sie bitte die Sicherung Bitte stellen Sie sicher dass das Radio eingeschaltet ist ber...

Page 13: ...and the speci ed electric current is 16A 9 This equipment not supply to the people who with low corporeity slow reaction or mental impedient and including children if this or such people need to use t...

Page 14: ...Water and Power Sketch Map 1550 775 1550 830 14...

Page 15: ...InstalllatIon Sketch Technical parameter Model Specif ied Voltage V 220 110 Frequency Hz 50 60 Water pump w 2 0HP Blower w 300 The maximum size mm 1550x1550x830 Whirlpool C654S 830 15...

Page 16: ...ot water switch Lift the hand of the handle of cool hot water switch outwards turn left can ow hot water 4 The below ketch shows the distribute water switch turn the distribute water switch make the r...

Page 17: ...r device with bathtub If the drainage was jammed after the steam room has already been used for some time should clean out the deodorizing drainage the following sketch B Cleanness of the valve that d...

Page 18: ...supply is abnormal 2 The strength adjusting does not act 3 The large air pipe not been inserted closely 1 Insert the plug closely 2 Adjust the strength adjusting 3 Insert the air pipe closely The wate...

Page 19: ...of chromium plating parts Wipe the chromium plating parts lightly with the cotton f lannel make sure not to polish with the coarse cloth Can t control The control line not be connected well 1 Reconne...

Page 20: ...state of no water 12 After the bathtub been installed seal up all connection slot between the bathtub and the wall body with the white neutral glass cement and can use it formally 24 hours later 13 B...

Page 21: ...ization function SELECTABLE 6 Expand audio input function 9 Touch Technology function 1 Highly sensitive water level sensor 10 Exterior heating apparatus funtion SELECTABLE 4 FM Digital Turing Radio a...

Page 22: ...3 SYSTEM INSTALL SKETCH 16A Leakage Switch Optional 22...

Page 23: ...ATHTUB CONTROLLER MODEL GD 7001BT VOLTAGE AC220 240V50 60HZ MAX TOTAL LOAD 14 2A WATERPROOFGRADE IPX4 SPECIFICATION FOR LOAD WATER PUMP AC220 240V1000W AIR PUMP AC220 240V 750W HEATER AC220 240V1500W...

Page 24: ...ing 1 Surf ing section After turning on the creepage switch the system will be electri ed and pressing of power 7 OPERATION INSTRUCTION Mode has heating function can set the Preferences temperature mu...

Page 25: ...h off the sur ng function by pressing sur ng key on the panel Then the sur ng pump will stop running and the sur ng sign on the screen will disappear Note A When the water in the bathtub Does not reac...

Page 26: ...in this Number The total memory for station is 20 If the received broadcasting station is not ideal please pull our antenna and adjust the direction fo antenna 4 Repeated hearing Press the key for sel...

Page 27: ...result 1 The antenna has not pulled out 2 The radio frequency has not been adjusted properly 3 The user is in weak signal area 1 Pull out the antenna and place properly 2 Readjust radio frequency prop...

Reviews: