After the system is off and the bathtub is no water for 30 seconds
detects water in 10 minutes). The ozone function will auto be work.
Failure Description
The LED light of the control box:
a. LIT means the control box doesn't connect power.
b. Always ON means the control box fails to communicate with the control panel.
c. FLASH means the control box is in normal work.
The display area shows::
E2 means communications failure.
E16 means the temperature probe is broken circuit.
E17means the temperature probe is short circuit.
Technical parameters:
Rated Working condition and characteristic
Rated voltage
AC220
Frequency
50Hz
Rated current
30A
Rated power
3.5KW
Insulation resistance
>20MΩ
Waterproof
IP65
Load parameters
Loads
Rated voltage
Frequency
Rated power
Other
Thermostat
AC220V
50Hz
2KW
-
Water Pump
AC220V
50Hz
2HP
-
Air Pump
AC220V
50Hz
800W
-
Light
DC12V
-
5W
-
Ozone
DC12V
-
6W
-
Speaker
-
-
8
Ohm
10w
-
USB
-
-
Fitting parameters
Control panel
Rated voltage
Rated power
Standby power
Waterproof
Communication
Size
Control panel
Control box
Installation wiring diagram