background image

Notice

1.This product needs to be installed and debugged by a qualified electrician.

2.The power supply of this product should has special circuits, there must be good grounding 

line of protection, the cable should be fixed for ever, the sectional area of the power supply cable 

should  be  thicker  than  ≥  4mm2,  users  must  install  electric  leakage  switches  in  the  supply  line 

that the movement electric current is 30mA and the specified electric current is 16A. 

3.The  power  as  AC  220V  ±10%,  50HZ.  (Products  for  export  is  customized  as  required). 

AC110/60Hz also available.

 4.The water pressure as 0.2~0.6Mpa.

5.The temperature of hot water supplied to the bathtub Should be cooler than 70

℃.

6. Maintaining must go on under the disconnection power.

2. The products of our company are altered the old and bringing forth the new constantly, if

has content difference with the original manual, will not issue a separate notice, please forgive.

1. The content in this manual, is the total introduction for the function of all types and conf

iguration, it is not all models that have these functions and conf iguration. 

9.This equipment not supply to the people who with low corporeity, slow reaction or mental 

impedient,  and  including  children,  if  this  or  such  people  need  to  use  this  equipment  that  a 

security responsibility for the guidance or assistance of safe is require. Children must be under 

the protection of an adult to use this equipment, so as to ensure its process is not in the shower 

caused play equipment unknown danger.

8. Strictly  prohibit  to  start  the  water  pump  while  no  water,  so  as  not  to  damage  the  seal

gasket of the water pump.

7. A child, old man without self-care ability mustn't use alone.

10.The grounding quipment should always be connected to the fixed cabling. And It should 

be install a whole extreme switch on the location of over 3mm of the connection point in the fixed 

cabling.

Note:

13

Summary of Contents for Whirpool C653

Page 1: ...1 Ordernummer __________ Seriennummer __________ Wichtige Informationen...

Page 2: ...it entsprech ender Verkleidung versehen werden 6 Das Ger t kann von Kindern von mindestens 8 Jahren und von Personen mit eingeschr nkten k rperlichen und geistigen F higkeiten wie auch von Menschen mi...

Page 3: ...Whirpool C653 USER MANUAL 185x160x68cm Wasservolumen Minimum 400 Liter Wasservolumen Maximum 500 Liter Gewicht ca 120 kg Montage und Bedienungsanweisung Instructions for installation operation 3...

Page 4: ...Trouble analysis and obviation Maintenance Instructions for use the control panel System install sketch Operation instructions HINWEISE ZUM AUFBAU BEDIENUNGSANLEITUNG INSTANDHALTUNG SICHERHEITSHINWEIS...

Page 5: ...agerecht aus wasserdicht sind Legen Sie die Anschl sse f r Wasser Zoll Strom und Ab uss 1 Zoll gem der Skizzen siehe unten Sie die Badewanne anschlie en und mit den Wasser sowie Stromanschl ssen verbi...

Page 6: ...und die Intensit t steuern Wasserablauf Drehen Sie den Wasserablaufknopf knob 2 im Uhrzeigersinn f r nicht weiter als ca 45 Grad um das Ab ussventil anzuheben damit das Wasser aus der Badewanne ablau...

Page 7: ...das Ger t zuerst aus bevor Sie das Wasser ablaufen lassen um Wasserr ckstau in SICHERHEITSHINWEISE Lassen Sie die Luftd senmassage aus Sicherheitsgr nden nicht l nger als eine Stunde laufen Lassen Sie...

Page 8: ...Input ANT Main box Water Sensor Bubble Bath Pump Speaker Lamp Heater Ozone Pump Computerpanel Stromanschluss Antenne Elektronikbox Wasserstandserkennung Luftpumpe Lautsprecher Beleuchtung Heizung Ozon...

Page 9: ...u pumpe Heizung Lautsprecher Beleuchtung Ozonreinigung Wasserstandser kennung Antenne MASSAGE BATHTUB CONTROLLER MODEL GD 7001BT VOLTAGE AC220 240V50 60HZ MAX TOTAL LOAD 14 2A WATERPROOFGRADE IPX4 SPE...

Page 10: ...er Ozone Set FM AUX LCD Anzeige Abw rts Aufw rts Beleuchtung Luftpumpe Wasserpumpe Ein Ausschalten Heizung zur Aktivierung 2 Sekunden gedr ckt halten Ozonreinigung zur Aktivierung 2 Sekunden gedr ckt...

Page 11: ...erscheint TUN Mit den Aufw rts und Abw rts Tasten k nnen Sie die Frequenz ndern Dr cken Sie die Taste um die Radiofunktion zu aktivieren Auf der Anzeige werden die Frequenz und die Lautst rke angezeig...

Page 12: ...uchtung Lautsprecher und hnliche sind nicht intakt Bitte stellen Sie sicher dass das Radio eingeschaltet ist berpr fen Sie ob durch erh hen der Lautst rke nun Ton wiedergegeben wird Sollte dies nicht...

Page 13: ...ce with the original manual will not issue a separate notice please forgive 1 The content in this manual is the total introduction for the function of all types and conf iguration it is not all models...

Page 14: ...Water and Power Sketch Map 14...

Page 15: ...InstalllatIon Sketch Technical parameter Model Specif ied Voltage V 220 110 Frequency Hz 50 60 Water pump w 1 1 5 1 1 0HP Blower w 400 The maximum size mm 1850x1600x680 Whirlpool C653 15...

Page 16: ...ot water switch Lift the hand of the handle of cool hot water switch outwards turn left can ow hot water 4 The below ketch shows the distribute water switch turn the distribute water switch make the r...

Page 17: ...can close the valve 1 B Cleanness of the valve that drain off water If the drainage was jammed after the steam room has already been used for some time should clean out the deodorizing drainage the fo...

Page 18: ...supply is abnormal 2 The strength adjusting does not act 3 The large air pipe not been inserted closely 1 Insert the plug closely 2 Adjust the strength adjusting 3 Insert the air pipe closely The wate...

Page 19: ...ed with citric acid had better soft cloth soaked with hot citric acid some dirties cant be wiped out by soft cloth pained with toothpaste Can t control The control line not be connected well 1 Reconne...

Page 20: ...s request to clearn with soft cotton towels lightly and let it dried naturally In order to avoid circuit fault the circuit can not contact with the water during clearning 14 The grounding quipment sho...

Page 21: ...s many functions 4 FM Digital Turing Radio and Double Power Amplifier 6 Expand audio input function 8 Almighty remote controller 9 Touch Technology function 7 Underwater lamp function 5 Ozone steriliz...

Page 22: ...3 SYSTEM INSTALL SKETCH Leakage Switch Optional Air pump Heater Water pump 22...

Page 23: ...ATHTUB CONTROLLER MODEL GD 7001BT VOLTAGE AC220 240V50 60HZ MAX TOTAL LOAD 14 2A WATERPROOFGRADE IPX4 SPECIFICATION FOR LOAD WATER PUMP AC220 240V1000W AIR PUMP AC220 240V 750W HEATER AC220 240V1500W...

Page 24: ...lay the Switching off The system can be directly switched off by pressing according to the requirement of users 7 OPERATION INSTRUCTION Mode has heating function can set the Preferences temperature mu...

Page 25: ...ssing sur ng key on the panel Then the sur ng pump will stop running and the sur ng sign on the screen will disappear Note A When the water in the bathtub Does not reach standard level the surfing pum...

Page 26: ...tion Spot pressing is for manual selection When the key is pressed for more than 2 seconds the frequency will move upward or downward automatically until the broadcasting station is received In the ca...

Page 27: ...result 1 The antenna has not pulled out 2 The radio frequency has not been adjusted properly 3 The user is in weak signal area 1 Pull out the antenna and place properly 2 Readjust radio frequency prop...

Reviews: