Automatic On / Off
The compressor is equipped with an automatic On/Off pressure switch. The compressor will only run when
the switch is in the “I” or “On” position. Once the tank has reached the
maximum preset pressure
, the
pump will
automatically
shut off. The pump will
automatically
turn back on once the pressure in the tank
drops
below
the
minimum preset pressure
.
The maximum and minimum pressures are set at the factory. Any attempt
by the operator to change them will void the warranty of the product
.
Overload Protection
This compressor is equipped with overload protection. In the event of a motor overload, the compressor will
cease to operate.
Possible Causes of Motor Overload are as follows:
1) Inadequate power supply.
2) Use of extension leads.
3) Overheating.
4) Lack of lubricating oil.
If such a shut down occurs, the Reset Procedure, as detailed below should be followed.
Reset Procedure
This compressor has a thermal cut off switch. If the compressor cuts out in anything other than its normal
duty cycle, you must:
1) Disconnect compressor from power source.
2) Leave the unit to cool down for 30- 60 minutes
3) Restart the compressor as per normal.