6
M017837080000 REV. January 19, 2011
2EZ Speed
TM
Pool Motor with Programmable Control/Timer
M017837080000 REV. January 19, 2011
7
2EZ Speed
TM
Pool Motor with Programmable Control/Timer
user Interface Identi cation
This section describes the motor’s user interface.
run/SToP
button. This button is used to activate or stop the unit operation. The button
will be not be lit when power is applied to the user interface while in STOP mode and
will be illuminated if in the run mode.
NOTICE
!
This button does
noT
disconnect
power to the unit.
Press the
EnTEr
button to confirm and save your selections. Use the
arrow keys
for menu navigation purposes and the
keys for changing values. For example, while
changing the time,
keys will move you from the hours to the minute’s field, while
the
keys will change the hour from 10 to 11 etc.
High Speed override
– Runs the motor on high speed and sets countdown timer for
60 minutes and will begin counting down. Pressing the button again will end override.
Low Speed override
– Runs the motor on low speed and sets countdown timer for
60 minutes and will begin counting down. Pressing the button again will end override.
1
2
3
4
General Installation Instructions
Follow these instructions to prolong the life of your
swimming pool pump motor/control.
a.
Protection against Heat
• Shade the motor/control from the sun.
• Provide ample cross ventilation.
• Protect the motor/control from lint, etc.,
that can plug the ventilation openings.
b.
Protection against Dirt
• Keep motor/control and surrounding area clean.
• Avoid sweeping or stirring dust near the motor/
control while it is running.
• Avoid storing or spilling dry chemicals near
the motor/control.
c.
Protection against Moisture
• Shade the motor/control from rain, snow, etc.
• Do not wrap motor/control with plastic or other
air tight materials.
• Locate motor/control on a slight elevation so water
will not run or puddle nearby.
• Avoid splashing water on or near the motor/control.
• Contact qualified service person to repair leaky
pipe joints or pump seals promptly.
Basic Motor/Timer operation
WARNING
!
A properly un tionin motor may
e too hot to tou h and ause in ury
Be careful when
touching the exterior of an operating motor! This condition
is normal for most motors when operated at rated load
and voltage.
Your 2EZ Speed
TM
motor/timer has been fully tested for
pool pump use before shipment. It is designed to be a
drop-in replacement for a standard single or two-speed
pool pump motor with only minor programming required.
To operate the motor control/timer, the installer must first
set the time of day and the day of the week. Please see the
specific sections of this manual for additional information.
Visually re-inspect the installation. Make sure that guards
and other protective devices are securely in place.
All covers and gaskets must be re-installed to minimize
the entry of dirt and moisture.
www.nidec-motor.com/Pool
MEnu
HIGH SPEED
o ErrIDE
LoW SPEED
o ErrIDE
run / SToP
Low High
1 : AM
MTuWThFSaSu
Program
Press Enter to Con rm
Set Clock
Set on Time
Set off Time
override
EnTEr
1
3
4
2
Summary of Contents for BADU ECOM2/S90
Page 1: ...Installation Operating and Service Manual BADU EcoM2 S90 Swimming Pool Pump...
Page 27: ......
Page 28: ......