Part # M017898010000 August 31, 2012
21
ECOTECH EZ
®
Variable Speed Motor/Control
Starting the Pump and Motor/Control
If the
RUN/STOP
button is illuminated, the motor is in the
RUN mode. If the Clock is set and the time of day and day
of week corresponds to a scheduled Program On time,
the motor will automatically ramp up to speed within a
few seconds. Be aware the unit will start in Prime mode
running at full speed for four minutes. After the priming
percent demanded by the operating mode which caused
the pump to start. When the unit is in Prime mode, the
Pressing the
Run Custom Flow
button followed by the
ENTER
button will start the pump in the current Custom Flow
1 setting. To start the pump in the Custom Flow # 2 setting,
press
Run Custom Flow
twice before pressing
ENTER
;
Press the
Run Custom Flow
button three (3) times then
press
ENTER
to Run Custom Flow 3 and Press the
Run
Custom Flow
button Four (4) times then press the
ENTER
button to start the pump in the Run Custom Flow 4 mode.
Stopping the Pump and Motor/Control
Press the RUN/STOP button to stop the pump.
The button will no longer be illuminated.
Running the ECOTECH EZ
®
Motor/Control
per the Program Schedule
The
RUN/STOP
button must be illuminated. The
motor/control will turn on and off automatically at the
programmed start and stop times and it will operate at
format, the current time of day, the current day of the
week, and the current or next Program Schedule that
will run. The Program Schedule may be overridden by
pressing the
Run Custom Flow
button or by pressing
the
Run MAX Flow/Vacuum
button.
The user interface includes two programmable % Flow
time periods for weekdays, Monday through Friday, and
two programmable % Flow steps for weekends, Saturday
and Sunday. These are the times at which the motor/
control will turn on and operate at the programmed
The Default or preprogrammed settings are as follows:
Mon – Fri Flow 1: 7:30AM Time On and 4:00PM Time Off
running at 50% Flow
Mon – Fri Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 70% Flow
Sat –Sun Flow 1: 7:30AM Time On and 4:00PM Time Off
running at 50% Flow
Sat – Sun Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 70% Flow
Custom Flow 1 80% 120 min
Custom Flow 2 55% 240 min
Custom Flow 3 0% 10 min
Custom Flow 4 0% 10 min
You can also schedule the unit with overlapping
program schedules. An example:
Mon – Fri Flow 1: 7:30AM Time On and 8:00PM Time Off
running at 40% Flow
Mon – Fri Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 70% Flow
Sat – Sun Flow 1: 7:30AM Time On and 8:00PM Time Off
running at 45% Flow
Sat – Sun Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 75% Flow
6:00PM. At 6:00PM, the pump will revert back to the 40%
Flow rate until 8:00PM. The same logic also applies to the
above weekend program schedule. This feature could be
used to save energy dollars by running the pump longer
For 24 Hour Operation
Setting the same On and Off times may cause the unit not
to run. An example:
Mon – Fri Flow 1: 6:00 AM Time On and 6:00 AM Time Off
running at XX%.
The unit will turn on and off at the same time and will not
run.
The recommended schedule for 24 hour operation is by
using both Mon – Fri or Sat – Sun Flows. An example:
Mon – Fri Flow 1: 7:00AM Time On and 7:00PM Time Off
running at 40% Flow
Mon – Fri Flow 2: 7:00PM Time On and 7:00AM Time Off
running at 40% Flow
Sat – Sun Flow 1: 7:00AM Time On and 7:00PM Time Off
running at 40% Flow
Sat – Sun Flow 2: 7:00PM Time On and 7:00AM Time Off
running at 40% Flow