Installation:

Wattage Selection

Note:

It is important that before making any connections with the speaker terminals on your 

NXC Series

that your power source, amplifier and/or receiver, is completely turned off.

First, determine the purpose that your 

NXC Series

will be used for by determining whether it will be 

used in a 70 Volt, 25 Volt or 8 ohms application.

Remove your speaker systems from the carton and remove the paint shield that is over the face of each

speaker.

Once you have removed the paint shield and determined that your application is either is for 70 Volt or 25

Volt commercial use, you must determine which wattage tap setting best meets the need of the sound

environment your speaker will be utilized in.

Usually, a wattage tap dial sets at “1.2W” – “2.0W” will be utilized for background music in a quiet office

setting.  The higher wattage taps “5.0W” – 60W” are utilized when a higher volume for the speaker is 

needed to offset a louder environment. After determining your need, gently turn the wattage tap dial on

the faceplate of each speaker with a small flathead screwdriver so that the silver-colored indicator is

aligned with the desired wattage tap on the corresponding “70V” or “25V” side of the transformer dial. 

Your transformer setting is then set and the NXC speaker will intuitively know whether it is receiving a 

70 or 25 Volt run.

For an 8 ohms speaker requirement, turn dial tap so that the silver indicator aligns with the 8 ohms 

indication on the dial.  This automatically overrides the transformer within the unit.

Connecting Speaker Wire

To correctly wire your speaker systems, carefully remove the terminal metal cover protecting the terminals

on the back of your speakers by unscrewing the fastened screws in each of the two corners. When the

terminal metal cover is removed, loosen the screws on the strain-protector portion of the terminal cover

and pass the speaker wire through the strain-protector. 

After passing the pre-laid wire through the strain-protector, remove the gray-numbered quick-snap 

terminal connect from the back of the speaker by slowly pulling it straight out of the terminals. 

On desired Parallel Runs, use the positive wire entering from the amplifier to enter and leave through 

terminal #2. The common wire running back to the amplifier should enter and leave through terminal #3

to wire your run as shown in the following example:

On desired Loop Through Runs, have the positive wire from amplifier enter through terminal # 2 and exit

through terminal #1, then have common wire running from other speakers in the run enter through termi-

nal #4, eventually heading back to the amplifier through terminal #3. See following diagram:

Once the wires are in, firmly tighten the small screws above each terminal until the wires are firmly

secured.

Upon securing, gently snap the quick-snap terminal connects back into place making sure it is lined up

properly and the text of the numbers on the quick-snap terminal connects match the same direction as the

text of the positive/negative indications on the back of the speaker for proper fitting.

Once the quick-snap terminal connect is in place, re-cover and the terminals section by securing the ter-

minal metal cover to its original location. Upon securing the terminal metal cover, faster the screws on the 

strain-protector to secure and clamp down on the wires to prevent loosening during installation and 

post-installation.

A 3/4” diameter punch out hole is also available on the terminal metal cover for installations where solid

conduit or flex pipe is needed. A pipe clamp is included as well for this purpose. 

In addition, a metal safety loop accompanies the back of each speaker and is recommended for securing

a speaker run with a supporting cable.

After connecting each speaker, it is recommended that you quickly check the connections with sound prior

to final mounting installation to ensure that everything is installed properly and functioning well.

Installation:

Upon determining you have a strong wire connection with your NXC Series speakers, they must be 

flush-mounted.

To install in a sheetrock ceiling, turn easy-mount tabs inward to the body of the speaker, carefully place

speaker in the diameter of the pre-cut whole and tighten the four mounting screwing on the outer rim of

the speaker faceplate until secure.  This will cause the easy-mount tabs to clamp down behind the

sheetrock and secure the speaker.

On installations with drop ceilings, make sure your provide speaker brackets are firmly secure and 

assembled in the ceiling, then insert the wired speakers with easy mount tabs by following the directions

in the preceding paragraph.

Please make absolutely certain that all speakers are securely mounted and that your selected site of

mounting can support the speaker weight indefinitely. 

SPECO TECHNOLOGIES ASSUMES NO 

LIABILITY FOR MIS-INSTALLED OR MISPLACED SPEAKERS.

+

-

+

-

From Amplifier

Previous Speaker

To Next 

Speaker

+

-

+

-

From Amplifier

Previous Speaker

To Next 

Speaker

* Through this wiring method, if the quick-snap terminal connect is pulled out in the middle 

of a speaker run, subsequent speakers will stay connected.

* Through this wiring method, if the quick-snap terminal connect is pulled out in the middle 

of a speaker run, subsequent speakers will stay connected.

Summary of Contents for Nexus Contractor SP-5NXC/T

Page 1: ...SP 4NXC T SP 5NXC T SP 6NXC T Owner s Manual for Models 70 25V Commercial Speaker Systems 200 New Highway Amityville New York 11701 Outside Metro NY 1 800 645 5516 631 957 8700 www specotech com 8 04 ...

Page 2: ...ur brackets location cut holes through the ceiling tile that line up perfectly with the placement and diameter of the C Brackets Upon finalizing speaker location and cutting holes pre run speaker wire through ceiling to be available upon speaker installation Specifications 4 Polypropylene Coated Woofer with Rubber Surround 3 4 PEI Tweeter Frequency 60Hz 20kHz 10 Watt RMS 30 Watt Max Sensitivity 86...

Page 3: ... other speakers in the run enter through termi nal 4 eventually heading back to the amplifier through terminal 3 See following diagram Once the wires are in firmly tighten the small screws above each terminal until the wires are firmly secured Upon securing gently snap the quick snap terminal connects back into place making sure it is lined up properly and the text of the numbers on the quick snap...

Page 4: ...gies 200 New Highway Amityville New York 11701 631 957 8700 www specotech com NOTES 30 or 60 Watt 4 Zone Amplifiers with AM FM Tuner and CD Player Item Codes P 30FACD P 60FACD Also available in cassette version 15 30 60 120 Watt RMS Contractor Series Amplifiers Item Codes PBM 15 PBM 30 PBM 60 or PBM 120 Desktop MIC with XLR Connector Item Code MHL 5S 70 25V MA Series ABS Plastic Enclosure Speakers...

Reviews: