Chapter 3 Front Panel Control
Figure 26: setting Remote mode
3. Press the Modify button. The LED above the Modify button will light and flashing triangles will appear below the
parameter value.
4. Turn the jog shuttle until you reach the desired setting. An explanation of the settings is provided at the top of
this section.
5. Press Modify to accept the value. This leaves the setting mode; the jog shuttle is inactive.
6. Switch the PU IQE 12/38 off and on again so that the setting becomes active.
3.5.13 Baud Rate
The baud rate is used for RS-232 communication.
The default setting is 1200. You can change this according to your configuration.
To change the baud rate:
Press and hold Num, then press Operate to set the unit into Off mode.
2. Press the Setup button repeatedly until the display shows Baudrate.
Figure 27: Setting the baud rate
3. Press the Modify button. The LED above the Modify button will light and flashing triangles will appear below the
parameter value.
4. Enter a new value using one of the following methods:
■
Turn the jog shuttle until you reach the desired value.
■
Press and hold Num while entering the desired number using the numerical keys. The numbers are entered
from right to left.
5. Press Modify to accept the value. This leaves the setting mode; the jog shuttle and numerical keys are inactive.
PU IQE 12/383.0
April 26, 2013
29