background image

 

23 

Structure of IN-02 stress scanner data files 

Table 6.1 

Beginning of file 

Measurement time 1 

Measurement 1 

Measurement time 2 

Measurement 2 

… 

… 

Measurement 

series 1 

Measurement time N 

Measurement N 

Record separator (empty string) 

Measurement time 

(N+1) 

Measurement (N+1) 

Measurement time 

(N+2) 

Измерение (N+2) 

… 

… 

Measurement 

series 2 

Measurement time 

(N+M) 

Measurement 

(N+M) 

Record separator (empty string) 

… 

… 

… 

End of file 

 

6.3.4.2. Turn on the personal computer and  launch the 

IN-01m CONNECT application. 

6.3.4.3.  Insert the  connection  cable  into  the  mini-USB 

connector  of  the  electronic  unit  and  connect  it  to  the 
corresponding  connector  of  the  personal  computer,  while  the 
stress  scanner  screen  displays  a  message  about  establishing  a 
communication  channel  with  the  personal  computer  through 
the mini-USB connector of the electronic unit (Fig.3.7). 

 

6.3.4.4.  In  the  IN-01m  CONNECT  application,  open 

the File menu and select 

Receive data

 

24 

After  receiving  information  from  the  electronic 

memory of the metal stress scanner, a graph of the distribution 
of  the  measured  values  in  the  Cartesian  coordinate  system 
appears on the screen of the personal computer. 

6.3.4.5.  To  select  the  type  of  graphical  screen  of  the 

measured stress scanner values and to save them on a personal 
computer,  use  the  corresponding  menu  items  of  the  IN-01m 
CONNECT  application,  which  are  described  in  the  program's 
user guide. 

6.3.5.  To  disconnect  the  stress  scanner  from  the 

personal  computer,  disconnect  the  cable  from  the  mini-USB 
connector of the electronic unit. 

 
 

Summary of Contents for IN-02

Page 1: ...Spector Sci Tech LLC IN 02 METAL STRESS SCANNER USER MANUAL Russia Ufa 2020 2...

Page 2: ...he scanning type is designed for continuous monitoring of the value of the mechanical stress of the metal of a steel product a metal structure made of structural steel according to the distribution of...

Page 3: ...out the display backlight 16 0 5 when working with the display backlight 68 0 5 2 6 Operating time of stress scanner when powered from freshly charged element PP3 in hours at least 45 2 7 Time to set...

Page 4: ...ed in the housing of the magnetic measuring unit 1 is 4 5 7 2 1 3 6 8 8 powered by a constant electric current from the pulse voltage stabilizer 3 The electrical voltage from the output of the sensor...

Page 5: ...to connect the magnetic measuring unit 1 to the electronic unit 2 of the IN 02 metal stress scanner 3 3 4 2 Connector 10 is used to connect a memory card slot uSD flash card to the electronic unit of...

Page 6: ...t to improve the screen of digital readings 3 4 4 Button 6 is used to switch the measurement mode of the metal stress scanner When button 6 is enabled the stress scanner switches to dynamic measuremen...

Page 7: ...es with a complex surface shape inspection of the tightening force of steel studs and bolts in threaded connections 14 a b Fig 3 6 Displaying information on the IN 02 stress scanner screen when the me...

Page 8: ...rsonal computer appears on the screen Fig 3 7 Fig 3 7 Displaying information on the IN 02 stress scanner screen when connected to personal computer 16 Using the IN 01M CONNECT application pre installe...

Page 9: ...84 consumers must be met 18 5 PREPARING THE METAL STRESS SCANNER FOR WORK Preparation of the stress scanner for work includes preparation of the electronic unit magnetic measuring unit and preparation...

Page 10: ...cted surface of the steel product structure presence of areas with increased stressed state of the metal 20 coordinates of the location of areas with increased stressed state of metal on steel product...

Page 11: ...batteries that have used up their life Insert freshly charged batteries observing the polarity of the contacts and close the battery cover 22 6 3 Working with metal stress scanner memory 6 3 1 The str...

Page 12: ...anner screen displays a message about establishing a communication channel with the personal computer through the mini USB connector of the electronic unit Fig 3 7 6 3 4 4 In the IN 01m CONNECT applic...

Page 13: ...the stress scanner they must be replaced 7 5 Current repairs are made during the operation of the stress scanner At the same time faults detected during routine inspection are eliminated by replacing...

Page 14: ...must ensure their stable position exclude the possibility of collision with other objects as well as against the walls of the vehicle 9 5 Conditions of transportation temperature C from minus 30 to pl...

Page 15: ...11 0 11 5 12 14 5 650 400 5 6 8 0 8 5 10 11 Table A 2 r mT Steel grade B MPa Y MPa 0 Y B 3 350 210 0 62 1 69 2 0 09 2 470 325 1 06 1 38 2 43 2 79 2 98 17 1 520 350 1 38 3 12 4 12 Steel 20 420 230 1 3...

Page 16: ......

Reviews: