background image

 

- ambient temperature from minus 20ºC to plus 70ºC, 

- relative humidity up to 98 % at +25ºC, 

- atmospheric pressure from 84 kPa to 106.7 kPa. 
 
 

2. TECHNICAL SPECIFICATIONS 

 

2.1. The range of  measurement of the field  strength of 

the residual magnetization of the metal, mT: 

- from 0 to 20.00

 

2.2.  Measuring  range  of  mechanical  stress  of  metal  of 

steel products, metal structures, MPa: 

- from 0 to σ

B

  

where σ

B

 is the ultimate strength of the metal. 

 

2.3.  The  limit  of  the  allowed  basic  error  in  measuring 

the  mechanical  stress  of  the  metal  of  a  steel  product or  metal 
structure is determined by the formula: 

0.5 + 0.05 σ

 

(2.1) 

where σ

i

 is the stress scanner readout in MPa. 

2.4.  The  metal  stress  scanner  is  powered  by  3x18650 

elements with total nominal electric voltage of 11.1V. 

2.5.  Electric  current  consumed  from  a  freshly  charged 

PP3 element, mA: 

- when working without the display backlight 

- 16 ± 0.5

 

- when working with the display backlight 

- 68 ± 0.5 

2.6.  Operating  time  of  stress  scanner  when  powered 

from freshly charged element PP3, in hours, at least: 

- 45 

2.7.  Time  to  set  the  metal  stress  scanner's  operating 

mode, s, not more than: 

- 30 

2.8. Maximum speed of the inspection: 

- 7 m/min 

 

2.9. Time of continuous operation of the stress scanner, 

h, not less than:  

- 12 

2.10. Battery charge time, minutes, not more: 

- 250 

2.11.  The  stress  scanner  has  a  memory  card  with  a 

capacity of more than 60000 measurements.

 

 

2.12.  The  stress  scanner  has  a  standard  output  for 

transmitting  measured  information to a personal computer via 
a mini-USB connector. 

2.13. Overall dimensions, mm, not more than: 

- Electronic unit (length × width × thickness) 

 

- 210×110×44

 

- Magnetic measuring unit (length × width × height) 

 

- 260×150×30

 

- Magnetic measuring unit cable length 

-1500±200 

2.14. Weight, g: 

- Electronic unit with battery 

- 550 

- Magnetic measuring unit 

- 1300 

2.15. Average recovery time, h:  

- 5 

2.16. Full average service life, years: 

- 10 

2.17. Established service life, years: 

- 2 

 

 

 

Summary of Contents for IN-02

Page 1: ...Spector Sci Tech LLC IN 02 METAL STRESS SCANNER USER MANUAL Russia Ufa 2020 2...

Page 2: ...he scanning type is designed for continuous monitoring of the value of the mechanical stress of the metal of a steel product a metal structure made of structural steel according to the distribution of...

Page 3: ...out the display backlight 16 0 5 when working with the display backlight 68 0 5 2 6 Operating time of stress scanner when powered from freshly charged element PP3 in hours at least 45 2 7 Time to set...

Page 4: ...ed in the housing of the magnetic measuring unit 1 is 4 5 7 2 1 3 6 8 8 powered by a constant electric current from the pulse voltage stabilizer 3 The electrical voltage from the output of the sensor...

Page 5: ...to connect the magnetic measuring unit 1 to the electronic unit 2 of the IN 02 metal stress scanner 3 3 4 2 Connector 10 is used to connect a memory card slot uSD flash card to the electronic unit of...

Page 6: ...t to improve the screen of digital readings 3 4 4 Button 6 is used to switch the measurement mode of the metal stress scanner When button 6 is enabled the stress scanner switches to dynamic measuremen...

Page 7: ...es with a complex surface shape inspection of the tightening force of steel studs and bolts in threaded connections 14 a b Fig 3 6 Displaying information on the IN 02 stress scanner screen when the me...

Page 8: ...rsonal computer appears on the screen Fig 3 7 Fig 3 7 Displaying information on the IN 02 stress scanner screen when connected to personal computer 16 Using the IN 01M CONNECT application pre installe...

Page 9: ...84 consumers must be met 18 5 PREPARING THE METAL STRESS SCANNER FOR WORK Preparation of the stress scanner for work includes preparation of the electronic unit magnetic measuring unit and preparation...

Page 10: ...cted surface of the steel product structure presence of areas with increased stressed state of the metal 20 coordinates of the location of areas with increased stressed state of metal on steel product...

Page 11: ...batteries that have used up their life Insert freshly charged batteries observing the polarity of the contacts and close the battery cover 22 6 3 Working with metal stress scanner memory 6 3 1 The str...

Page 12: ...anner screen displays a message about establishing a communication channel with the personal computer through the mini USB connector of the electronic unit Fig 3 7 6 3 4 4 In the IN 01m CONNECT applic...

Page 13: ...the stress scanner they must be replaced 7 5 Current repairs are made during the operation of the stress scanner At the same time faults detected during routine inspection are eliminated by replacing...

Page 14: ...must ensure their stable position exclude the possibility of collision with other objects as well as against the walls of the vehicle 9 5 Conditions of transportation temperature C from minus 30 to pl...

Page 15: ...11 0 11 5 12 14 5 650 400 5 6 8 0 8 5 10 11 Table A 2 r mT Steel grade B MPa Y MPa 0 Y B 3 350 210 0 62 1 69 2 0 09 2 470 325 1 06 1 38 2 43 2 79 2 98 17 1 520 350 1 38 3 12 4 12 Steel 20 420 230 1 3...

Page 16: ......

Reviews: