Service Menu - External EDM Frequency
Press
N
and
O
to scroll to
Ext. EDM Frequency
and
then press
P
.
EDM Frequency
Press
P
to switch on the EDM Laser source with
modulated scale frequency.
Press
N
(ESC) to leave the menu.
EDM Frequency
C
WARNING –
The unit in frequency calibration
mode produces visible Laser light emerging at
the centre of the telescope objective. The
Laser light conforms to Class 3R. Make sure to
do the external EDM frequency calibration
appropriate to all warnings and precautions at
Nominal frequency will be displayed.
Press
P
to leave the menu.
Service Menu - Ext. EDM Calibration
Settings after external EDM calibration:
Press
N
or
O
to scroll to
Ext.EDM Calibration
and
press
P
.
C
WARNING –
Both values for
External EDM
Calibration
influence the measured distance
directly! Therefore, they must have been
determined by means of an accurate external
calibration.
Screen
Actions and Comments
Ext. EDM Frequency
System diagnose
Service Menu
USB Interface
Ext. EDM Calibration
Ext. EDM Frequency
Laser Class
3R
ESC
Ext. EDM Frequency
Laser Class
3R on!
f=400044548 Hz
Ext. EDM Calibration
Ext. EDM Frequency
Service Menu
System diagnose
Drive Mode