FOCUS 35 TOTAL STATION USER GUIDE
6 –
Instrument Technology
96
Instrument
Off Mode
•
Press the Trigger key for 1 second (single beep) to turn on the instrument.
Note –
During Off Mode the Trigger key LED is off.
On Mode
•
When starting the instrument it will enter a
Waiting mode
, where it will wait for an external
connection for about 5 minutes. While in waiting mode the Trigger key LED will flash once every
second and Face2 Display will show “Waiting”. During this time it is possible to start the
application program, or prepare the settings for robotic measurements. The StepDrive motor
system and Focus System are usable during this time.
•
If the instrument is not used for 5 minutes (default) the instrument will go to
Suspend Mode
and
Face2 display will show “Waiting (suspend)”.
•
To turn Off the instrument press the Trigger key for 3 seconds - one beep and one double beep.
•
The instrument will automatically enter
Suspend Mode
when the battery (including he Face 1
battery, if available) is removed.
•
The instrument will go to
Suspend Mode
if the battery is low (battery capacity less than 5%),
which enables you to replace the battery within a period of 10 to 15 minutes.
•
Without replacing the battery the instrument will go to
Off Mode
if the battery capacity is less
than 2 % and any unsaved data will be lost.
Note –
During On Mode the Trigger key LED will be on solid.
Suspend Mode
•
You can resume working from the same place in the software that you were before you entered
Suspend Mode
.
•
You can replace a discharged battery with a charged one within a period of 30 seconds.
•
In the suspend mode the Radio and the Face2 display will be enabled. Face2 display will show
“Waiting (suspend)”
•
To turn the instrument On
,
press the Trigger key for one second (one beep) or connect to the
instrument from a remote application.
•
To turn the instrument Off
,
press the Trigger key for 3 seconds.
•
In
Suspend Mode
the instrument will turn Off automatically at suspend time out (default
120 minutes).
Note –
During Suspend Mode the Trigger key LED will flash once every five seconds.
Robotic configuration
A separate control unit is via cable or radio connected with the instrument. For starting the
instrument see
.