Mask mode
Select the Mask icon and press and release
button 4
to open the
Mask setting menu
.
Depending on which side or corner the beam should be turned off, the required sector can
be selected.
Press and release the
buttons 5
to
8
for moving a short flashing line around the mask
mode symbol
.
For
selecting the sector
where the bar is flashing, press and release
button 1
(
SET
).
After setting the first sector,
button 1
changes to show
CLR
which offeres the capability
of deleting the selected mask sector again. Use
button 5
to
8
to move the flashing bar
to other required areas and repeat the setting process.
When all areas have been set, press
button 4
to
store the mask sector selection
until the
unit will be turned off.
Note:
The unit always powers up with the mask mode deactivated (default).
Standby Mode
Press and release the MENU button at the Standard Display and select
Standby
.
Pressing and releasing
button 4
activates the Standby mode.
The self-leveling will be stopped and the beam will be turned off while the HI alert
is still active.
The display shows the standby symbol and the Level/Standby LED flashes red every 5 seconds.
To deactivate Standby mode and restore full operation of the laser, press and release
button 4
.
Mask Mode / Standby