background image

Press and release the MENU button at the Standard Display and select 

Info

.

Buttons 6/7 

can be used to toggle between

UL, RC 

and

Runtime

Press and release 

button 4 

to confirm the selection. 

The UL/RC information (software version, ID, etc.) or the runtime of the UL will be displayed.

Additional detailed RC information is available using the RC603 menu :

Info

Summary of Contents for Trimble UL 633N

Page 1: ...UL633N Hands On training 11 07 17...

Page 2: ...pad LCD Display b Handle c Rotor with fan beam lens d Sunshade e Axes Alignment Marks f Sighting Guides Scope Mounts g Battery door h Rubber Cover Recharge Jack i 5 8 x 11 Tripod Mounts j Rubber Feet...

Page 3: ...e rechargeable battery pack can be charged inside as well as outside of the unit 3 The charger Q104781 can be used as a power supply when used Indoors 4 Alkaline batteries can be used as a backup 5 An...

Page 4: ...tab on the RC603N RC603N will be shipped with alkaline batteries Rechargeable batteries can be used optional but need to be charged externally 2 Insert two AA batteries noting the plus and minus diagr...

Page 5: ...grade entering mode Button 3 Quickly press and release activates deactivates the manual mode Button 4 Quickly press and release to toggle through the pre selected rotation speeds Press and hold for th...

Page 6: ...check the leveling time can be increased When the temperature reference check has been finished the standard display appears and the bubble symbols flash until self leveling has been completed Don t s...

Page 7: ...ont of the comma will be set to 0 and then starts changing in 1 increments Press and hold button 5 or 8 up down for changing Y Z axis grade value press and hold buttons 5 8 simultaneously starts Y Z a...

Page 8: ...e value and return to the standard display Press and release button 5 or 8 down or up to move the cursor to the X or Y axis not used in Z mode Pressing and releasing button 6 or 7 right or left moves...

Page 9: ...Press and hold button 4 at the Standard Display for three seconds to change the unit into scan mode Quickly press and release button 4 to toggle between the pre selected scan sizes 5 15 45 90 180 degr...

Page 10: ...al In Manual mode horizontal the Y axis can be sloped by pressing the Up 5 and Down 8 Arrow buttons on the laser s keypad or the remote control Additionally the X axis can be sloped by pressing the Le...

Page 11: ...arrow at the the right site indicates that the user can scroll up down through the menu rows 4 different screens using the buttons 5 8 up down arrows Pressing and releasing button 3 changes the unit...

Page 12: ...already paired remote with a new transmitter The new transmitter has to be set to the pairing dialog for this operation Otherwise the pairing can not be successful processed The pairing information o...

Page 13: ...ver should be permanently mounted at this location and at the desired elevation 3 Use the sighting guides on the top of the laser to align the laser to the receiver Turn the laser on the tripod until...

Page 14: ...at the HL760 display Note The laser continues to servo to the receiver s signals 6 Exiting of PlaneLok can be done by pressing button 3 ESC Note If the setup will be disturbed for a minute beam will b...

Page 15: ...he steep slope area using the slope bracket M402 laser tilting base Check the laser beam elevation and place the two receivers at the desired hubs Change the UL into manual mode and tilt the unit to t...

Page 16: ...017 16 Steep Slope using PlaneLok Select PlaneLok at the menu and start Dual Axis PlaneLok by pressing button 4 The transmitter starts searching for both receivers and locks the beam at the on grade p...

Page 17: ...ange on both axes is 40 4 Press and release the MENU button at the Standard Display and select Grade Match 5 Select the desired Grade Match axis then press button 4 to start Grade Match Note The laser...

Page 18: ...start manual Grade Match The grade for the Y axis can be adjusted with button 5 8 while button 6 7 adjust the X axis During Manual Grade Match a crossed vial and angle symbol appear next to the conti...

Page 19: ...urn the laser on the tripod until it is roughly aligned to the receiver s position the alignment range on both axes is 40 4 Press and release the MENU button at the Standard Display and select Axis Al...

Page 20: ...ment to the second direction point 5 After repeating step 2 and 3 the display shows the new alignment angle and the angle difference between the two direction points Edit Align Angles Selecting Edit A...

Page 21: ...8 to move the flashing bar to other required areas and repeat the setting process When all areas have been set press button 4 to store the mask sector selection until the unit will be turned off Note...

Page 22: ...starts the reference check considering the current temperature inside the housing While the procedure the rotation will be stopped Note A grade value has to be entered before the unit starts the refer...

Page 23: ...Buttons 6 7 can be used to toggle between UL RC and Runtime Press and release button 4 to confirm the selection The UL RC information software version ID etc or the runtime of the UL will be displayed...

Page 24: ...n procedure The RC603N Service menu offers additional features RF IR options Press and release button 4 to confirm the selection and select one of the following options RF On IR auto Radio on all time...

Page 25: ...button 4 activates the fan beam while the rotation speed changes to 750 rpm and the unit goes back to the standard display The 4 red LEDs around the center hole guide the user to the plumb beam s cent...

Page 26: ...4 Press and release the MENU button at the Standard Display and select Spot Align 5 Pressing and releasing button 4 starts the automatic spot alignment while the plumb beam becomes a rotating fan beam...

Page 27: ...at the second reference point 3 Press and release the MENU button at the Standard Display and select SpotLok 4 Pressing and releasing button 4 starts the automatic spot alignment while the plumb beam...

Page 28: ...t end of the trench 3 Press and release the MENU button at the Standard Display and select Spot Match 4 Pressing and releasing button 4 starts the automatic spot alignment while the plumb beam becomes...

Page 29: ...the manual button 3 to change the unit back to full automatic mode Beam Plunge Beam Plunge centers the rotor vertically and can be used to align the plumb beam to a desired vertical position e g when...

Page 30: ...using button 1 CLR 3 Turn on the RC603N and select the Pairing menu and press button 4 The UL633N pairs now automatically with the new remote control Setting Menu Pairing Grade Entry Display Sensitivi...

Page 31: ...display shows MENU first then RDIO Press and release the Units C button display shows the current radio mode If not already set to LS press Units button C and then press Deadband or Audio button unti...

Page 32: ...d Go and Digit Select Press and release button 4 to confirm the selection Grade Display Select the Grade Display icon and press and release button 4 to open the Grade Display menu The desired Grade Di...

Page 33: ...ected using the buttons 6 7 Press and release button 4 to confirm the selected HI alert User Name Select the User name icon and press and release button 4 to open the User name menu Cursor flashes One...

Page 34: ...urns off automatically Password On Off Select the Set Password ON Off icon and press and release button 4 to open the Password menu Buttons 6 7 can be used to toggle between Password On and Password O...

Page 35: ...s caused by different gravity The user has the chance to provide the position info of the job site to the product This is the degree of latitude as well as the altitude Chose Settings and navigate to...

Page 36: ...er not available for single axis automatic function Make sure the receiver is on and paired 151 No receivers Both receivers are not available for automatic alignment function Make sure both receivers...

Page 37: ...SF601 User Guide SF601 attached to a grade rod using the standard receiver clamp SF601 attached to the optional pipe laser target base...

Page 38: ...al 6 Battery LED 7 Mode LED 8 Red Direction LEDs 9 IR transmitters receivers 10 Marking notches front and back 11 M6 Clamp Mount 12 Battery door 13 Latch for Battery Door 14 Release Tab Slider SF601 C...

Page 39: ...power button for 1 sec to turn OFF the SF601 Note If the SF601 has been turned on a short button press activates deactivates the fan beam lens a previously chosen automatic mode will be exited automat...

Page 40: ...int both axes until exiting this mode Automatic Spot Match like Grade Match two existing elevation points will be connected to measure the grade value between these two points aligns the plumb beam au...

Page 41: ...er position of the fan beam Note IR communication to the UL633N is disabled The direction LEDs work similar like using the pipe laser target e g if the left top LED is on the SF601 has to be moved to...

Page 42: ...Sun Shield SF601 Mount w Rubber Strap Pins for Rubber strap Q104864 Sun Shield for longer range when the SF601 is used in bright sunlight Q104865 Spot Finder Adaptor incl Rubber Strap...

Page 43: ...Q104865 Mount SF601 Tripod Setup Tripod thread centered with the SF601 and tripod mounting threads...

Page 44: ...Q104865 Mount SF601 Batter Board Setup Marking notch aligned with the center of the nail Clamp thread for attaching the receiver clamp...

Page 45: ...Q104865 Mount SF601 Free Standing Setup Marking notches on both sites...

Reviews: