Cleaning Procedure:
You will need 10 gal (38 L) of chlorine free water and the system must have already
been thoroughly flushed. Mix the bag of Spectra Watermakers cleaning chemical into
the water and stir until well dissolved. Some chemical may remain out of solution in
the bucket, this is normal.
Open the Pressure Relief Valve on the Pearson Pump.
You will need 1 bag of the cleaning chemical to be used, 10 gal. (38L) of chlorine free
water, and the system must have already been thoroughly flushed. The feed water
supply must be shut off.
Mix the bag of Spectra Watermakers cleaning chemical into a bucket of the
unchlorinated water, stir until well dissolved.
Attach the service hoses, place the open ends of
the hoses in the bucket and turn both the service
valves to SERVICE (valves in picture shown in run
position)
Use the Service toggle switch on the front of the
control panel to run the pump.
Circulate cleaning chemicals for up to 6 hours
depending on the level of fouling present (contact
Tech Support for advise on cleaning).
Turn both the service valves to the off position
(vertical)
Leave the pressure relief knob open.
The prefilter housings should be drained and new
filters installed.
Leave the pressure relief knob open.
The watermaker can now be stored for up to
six months. If the machine has not been used for six months the preservative
procedure should be repeated.