47
GEARCASE LUBE OIL
Use only Spectra PP-CC-CCO, or source ISO 68 petroleum oil locally
Spectra-Pearson Pump crankcase. Do not overfill the crankcase with oil. Check oil
condition and level frequently and it should be changed every 5000 hours of operation
or annually, whichever comes first.
The Spectra– Pearson Pump comes mounted on a CAT
™
crankcase.
Inspect the oil
level and condition often.
The oil in the crankcase should be changed every 5,000 hours or when the oil appears
milky. Note that if the oil appears milky it is time to change the seals as water is get-
ting into the crankcase from the pump head. There is a dip stick at the back of the
crankcase to check the oil level.
Vented Oil Cap
Dip Stick (centered in
the top/back of the
case)
Drain Plug
(centered in the bot-
tom/back of the case)
1. The oil will drain better if it is warm, after the system has been running for a few
hours.
2. Find a suitable container to drain the oil into, remove drain plug.
3. Replace drain tube and refill with 2-1/2 quarts (2.5 liters)
PP-CC-CCO, or source ISO 68 petroleum oil locally
Please dispose of used oil responsibly.
CHANGING THE OIL
Oil Changes