19
Wiring 700/1000 24V DC Systems
DC Systems will have:
Fresh water flush cable, these wires have no polarity
A Power inlet harness with a terminal block,
A 75’(26 M) cable with connectors for the MPC-3000 control display,
Clark pump module harness consisting of the Rotoflow cable, salinity probe cable, and the
diversion valve (no polarity) cable.
The MPC-3000 Control box houses the
Pulse Width Modulation
motor speed control and
the MPC-3000 control board. On the motor speed control are two potentiometers used to set
the run, flush, and service speeds. The speed control has over-temperature shutdown pro-
tection.
Do not install it in hot or poorly ventilated locations
.
Fresh water flush cable
Power inlet terminal
block w/ cover
RED POSITIVE
YELLOW NEGATIVE
75’ (26M) cable with
connectors for the MPC-
3000 control display
Clark Pump Harness
Salinity probe cable
Diversion valve cable
Rotoflow cable
Manual Control
Switches
DC Speed Control
w/ speed adjusting
potentiometers.
MPC-3000 circuit
board