background image

SpectraPure

SpectraPure®Inc.

  

480.894.5437   Call us toll-free  1.800.685.2783    

2167 East Fifth St,    Tempe, Arizona   85281

®

4

SYSTEM SPECIFICATIONS

Sediment Pre-Filter 

 

0.5 micron MicroTec™  sediment pre-filter

Carbon Filter  

 

 

0.5 micron carbon block pre-filter

RO Membrane Type   

Thin-Film Composite  (TFC)

DI 

Cartridges 

   

M

AX

C

AP

 DI ™ 

      SilicaBuster™ 

DI

Rejection Rate   

 

Greater than 98% average

Input Water Pressure 

60 psi (4.15 bar) line pressure*

Input Water Temp    

77°F (25°C)

Recovery Rate   

 

20% (i.e. 20% of the water will be

      collected 

as 

pure 

water)

Nominal Membrane Flow Rates @ 60 psi  & 77° F :
 

GPD (lpd) 

Product Water Flow Rate   

Concentrate Flow Rate

 

   90 (340) 

  

235ml/min   

 

 

 

940 ml/min

 

   150 (340)    

235ml/min   

 

 

 

940 ml/min

 

   300 (680)   

470ml/min   

 

 

       1880 ml/min

Reverse Osmosis Membrane Feed Water Requirements

For the 1 year SpectraSelect TFC membrane pro-rated warranty to be honored, the 
following conditions must be met:

Operating Pressure*   

 

 

40 – 80 psi (2.75 – 5.5 bar)

pH 

Range      3 

– 

11

Maximum Temperature 

 

 

100° F (38° C)

Maximum 

Turbidity    1.0 

NTU

Maximum Silt Density Index 

 

5.0 (based on 15 min. test time)

Maximum Chlorine 

 

 

 

less than 0.1 ppm

Maximum 

TDS     2000 

ppm

Maximum Hardness   

 

 

10 grains (170 ppm as CaCO3)

Maximum 

Iron     less 

than 

0.1 

ppm

Maximum Manganese  

 

 

less than 0.1 ppm

Maximum Hydrogen Sulfide 

 

0 ppm

Langlier Saturation Index   

 

LSI must be negative

*Operating pressure less than 40 psi will require a booster pump:

less than 49 GPD use BPLF-MO-115(-230),

more than 49 GPD use BPHF-MO-115(-230).

*Operating pressure greater than 80 psi will require a pressure reducing valve.

SpectraPure®Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: spectra@spectrapure.com Visit us on the web www.spectrapure.com

21

SpectraPure

®

TESTING THE PERFORMANCE OF THE MEMBRANE

Membrane Output Calculation

Membranes produce the rated gallons per day (GPD) at 60 psi (4.1 bars) operat-
ing pressure, 77°F (25°C) operating temperature and 500 ppm total dissolved 
solids.

Membrane output gallons per day (GPD) depends on operating pressure, water 
temperature and the ppm TDS in the feed water.
 
Expected GPD = Rated GPD × PCF × TCF

PCF

 is the pressure correction factor

TCF

 is the temperature correction factor

Calculation of Pressure Correction Factor (PCF): 

The output (GPD) from 

the membrane is directly proportional to the applied pressure. 

Note: The membrane is rated to produce the rated GPD at 60 psi. For any pres-
sure other than 60 psi the output GPD is multipled by the PCF.

PCF = Line Pressure (in psi) ÷ 60 

Calculation of Temperature Correction Factor (TCF): 

The output (GPD) 

also decreases with decrease in temperature. This is because water viscosity 
increases with decrease in water temperature.

Temperature Correction Factor Table (TCF)

°F 

/°C  TCF 

  °F 

\°C  TCF 

  °F 

\°C  TCF

41.0 /5   

0.521 

 

59.0 /15  

0.730 

 

77.0 /25  

1.000

42.8 /6   

0.540 

 

60.8 /16  

0.754 

 

78.8 /26  

1.031

44.6 /7   

0.560 

 

62.6 /17  

0.779 

 

80.6 /27  

1.063

46.4 /8   

0.578 

 

64.4 /18  

0.804 

 

82.4 /28  

1.094

48.2 /9   

0.598 

 

66.2 /19  

0.830 

 

84.2 /29  

1.127

50.0 /10  

0.620 

 

68.0 /20  

0.857 

 

86.0 /30  

1.161

51.8 /11  

0.640 

 

69.8 /21  

0.884 

 

87.8 /31  

1.196

53.6 /12  

0.661 

 

71.6 /22  

0.912 

 

89.6 /32  

1.232

55.4 /13  

0.684 

 

73.4 /23  

0.941 

 

91.4 /33  

1.267

57.2/14 

 0.707  75.2 

/24 

 0.970  93.2 

/34 

 1.304

Summary of Contents for THE MAXCAP RO/DI System

Page 1: ...ilter Wrench Optional Accessories Model Optional Part FAU SMP Quick Connect Faucet Coupler TK CL 10 Total Chlorine Test Kit VA FVK 4 Flush Valve Kit BPLF MO 115 Low Flow Booster Pump 115V BPLF MO 230...

Page 2: ...for any consequential damages arising from installation or use of the product including any water or mold damage due to flooding which may occur due to malfunction or faulty installation including bu...

Page 3: ...ered purchaser After repair or replacement the factory will return the unit or part freight prepaid to the customer 2 We assume no warranty liability in connection with our equipment other than as her...

Page 4: ...sure greater than 80 psi will require a pressure reducing valve SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com...

Page 5: ...water is passed through a 0 5 micron Micro Tec sediment pre filter This filter is required to remove excess turbidity particulate matter that may cause the carbon block filter to plug 2 The second st...

Page 6: ...ure When the prefilters are new the pressure shown on the gauge will be slightly less than the actual tap water pressure and as the filters age the pressure will drop due to the dirt that will collect...

Page 7: ...vi Acidify feed water to the RO membrane to improve its rejection h Faulty monitor probe Test and Replace if required SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra s...

Page 8: ...at is located inside of the tubing Do not remove or discard this restrictor the system will not produce permeate water without the flow restrictor All of the following conditions must be met before wa...

Page 9: ...assure you of maximum life and reliability of your SpectraPure System Failure to perform this procedure can permanently damage the membrane and will void the pro rated Membrane Warranty In order to m...

Page 10: ...RO membrane may be calculated and the resultant number may then be used to determine the condition of the membrane and thus the operator will know when the membrane needs to be replaced Membrane failu...

Page 11: ...te the yellow concentrate tubing Fig C Remove the tubing from its push fitting at the membrane as follows a Firmly depress and hold the push fitting collar down with your thumbnail b While the push fi...