4
Installation Guide
[101]
to
[116]
= Zone 1 to Zone 16
[133]
=
Partition
1
[134]
= Partition 2
[135]
= Keypad Name (default: “Paradox Security”)
[500]
to
[507]
= Notes (this is what the user will see when the
[
HELP
]
key
is pressed)
[2] Options
In step 3 of “Entering Keypad Programming Mode” on page 3, select
option
[2]
. You will now be able to enable or disable the keypad’s
options as shown in Table 1. Press the corresponding keys until all
desired options are set, then press
[
ENTER
]
.
Table 1: Keypad Options
Bold
= Default
Keypad Zone Sending
Section
[2]
— Option
[1]
Off
= Disabled
On
= Enabled (default)
Key
Description
OFF
ON
[1]
Keypad Zone Sending
Disabled
Enabled
[2]
Keypad Zone Requires
1K
Ω
EOL Resistor
No
Yes
[3]
Keypad Zone Set to
Keypad Zone 1
Keypad Zone 2
[4]
On-Board Keypad Tamper
Supervision
Disabled
Enabled
[5]
Status LED Follows
Arming Status of
Partition 1
Partition 2
[6]
Multiple Zone Display
Disabled
Enabled
[7]
Scrolling Zone Display
Disabled (only if
[6]
= ON)
Enabled
[8]
Time Format
International
US (a.m./p.m.)