Spectracom Corporation
EPSILON CLOCK MODEL EC22S
EPSILON CLOCK User’s Manual
4-5
To modify a programmable field, use the direction keys to reach that field, then click "enter",
then select “content” with the left/right key.
To go back to the main menu screen, bring the cursor to the “Back” field and click "enter".
4.2.2 Screens
4.2.2.1
Main screen
30/05/2007 11:08:48U
[Clock Status]
-Setup-
-Extraction-
Select the desired operation in the main menu screen with the up/down keys and then click the
"enter" key to enter the operation screen.
Time is displayed according to the "Time Reference" parameter.
U stands for UTC referenced, L for Local (UTC + Local Time Offset), G for GPS, N for None
(time never initialized), and M for Manual (no GPS and manually set).
4.2.2.2
Clock Status screen
Left
Right
M/S
Master
Slave
AC
Alarm
Alarm
DC
OK
OK
[Back]
Useful additional information is displayed on the front panel when an operator wants to check
presence of power supplies (AC and DC), with a reminder of which Clock module is the source
of the distributed signal (Master).
Unlike the web display, the LCD display power alarms are never disabled, so that an operator
can always check the power supply connection.