background image

American English–11

1 609 929 E86  •  (02.12) T

The instrument monitors the correct functioning for ev-
ery measurement.  If a defect is detected, only the sym-
bol 

 blinks in the display (measurement from the

back end). Take the unit to your dealer for sending to
the Trimble Service Center.

The accuracy of the instrument can be checked as follows:

Select a distance that never changes that is approx. 1–10 m (3.3–

33 ft) long (e.g. room width, door opening) whose length is known ex-

actly.

Measure this distance ten times one after the other.

The measurement error can be a maximum of ±3 mm (±1/8 in).  Record
the measurements so that the accuracy can be compared at a later time.

Error – Cause and Correction

Cause

Correction

The temperature indicator k blinks, measuring is not possible

Measurement outside the allowed
temperature range from –10 

°C

(+14 °F) to +50 °C ( +122 °F).

Wait until the allowable temperature
range is reached.

“ERROR” Message and “------- m” in the Display

The angle between the laser beam
and the target is too acute.

Increase the angle between the
laser beam and the target.

The target surface reflects too
strongly (e.g. a mirror) or too weak-
ly (e.g. black material).

Use the target panel (accessory).

Ambient light is too strong 
(e.g. sunlight).

Use the target panel (accessory).

The receiving lens 

22

 or the laser

beam exit 

23

 are misted over, for

example, as a result of changing
between low and high environmen-
tal temperatures.

Wipe the receiving lens 

22

 or the

laser beam exit 

23

 dry with a soft

cloth.

Unreliable Measurement Results

The target surface does not reflect
clearly (e.g. water, glass).

Cover the target surface.

The laser beam exit 

23

 or the

receiving lens 

22

 is soiled.

Keep the laser beam exit 

23

 or the

receiving lens 

22

 free of dirt.

The corrective measures listed
above do not eliminate the error.

Take the unit to your dealer for
sending to the Trimble Service
Center.

Checking the Measurement Accuracy

Summary of Contents for Precision HD150

Page 1: ...29 0635 3120 28 0635 1490 0600 1320 17 0600 1310 18 0600 1340 3 0600 1330 30...

Page 2: ...A B C E D F...

Page 3: ...3 16 1 2 5 7 8 4 9 11 12 14 13 15 6 4 10 17 18 19 19 a b c d e f g h i k l m...

Page 4: ...21 20 4 24 26 27 25 22 23...

Page 5: ...asuring Instrument Order number HD 150 Measuring range natural surfaces 0 3 150 m 1 500 ft Measuring accuracy Typical 0 3 30 m 1 100 ft Maximum 2 mm 3 32 in 3 mm 1 8 in Measuring time Typical Maximum...

Page 6: ...utton 3 Bubble level 4 Aligning aid 5 Area measurement button 6 on off button 7 Measurement button Two step button for sighting and measuring 8 Display 9 Display lighting button Symbols Symbol Name Me...

Page 7: ...Positioning extension 28 Laser viewing glasses 29 Target panel 30 Protective bag Accessory parts included Optional accessories not included Display Elements a Laser switched on b Measurement function...

Page 8: ...ever open the unit yourself Trimble is able to ensure perfect functioning of the unit only if the orig inal accessories intended for it are used Protect the unit from moisture and direct sunrays Dirt...

Page 9: ...For areas or volume entries only units of m or ft are possible Measuring Procedure The instrument has several measuring functions that can be selected by pressing the respective function button see M...

Page 10: ...m mea surement If possible rest the instrument on or against the measuring point The measurement takes place at the middle point of the light spot also for obliquely illuminated target surfaces The me...

Page 11: ...ece The unit takes automatically into consideration the different lengths of the end pieces when measuring measurement in both cases from the rear end of the unit Bubble Level The bubble level makes p...

Page 12: ...ed For larger values switch to the m3 unit of measure by pressing the m ft button 10 Continuous Measurement see Fig The continuous measurement serves for the transfer of dimensions for example from co...

Page 13: ...ctor The best pos sible results are achieved only when the laser beam and the measured distance form an exact right angle Pythagorean theorem In the illustrated example the length C is to be determine...

Page 14: ...ue first In the display the symbol ap pears The counter at the right next to the symbol shows the numbering of the displayed values The measured values displayed can still be entered into memory by pr...

Page 15: ...F Wait until the allowable temperature range is reached ERROR Message and m in the Display The angle between the laser beam and the target is too acute Increase the angle between the laser beam and th...

Page 16: ...e Service Center In case of repair send in the unit in the protective bag 30 Recycle raw materials instead of disposing as waste The unit accessories and packaging should be sorted for environment fri...

Reviews: